BYRON, NY —
OSHA Inspection: DEWEY PRODUCE INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DEWEY PRODUCE INC. in 6997 TRANSIT ROAD, BYRON, NY 14422 (NAICS 424480). OSHA activity number 342799764.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DEWEY PRODUCE INC.
- Site address
- 6997 TRANSIT ROAD
- City
- BYRON
- State
- NY
- ZIP
- 14422
- Mailing
- 5966 GRISWOLD ROAD, BYRON, NY 14422
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424480
- Employees
- 10
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.28 B03 II
- Issued
- Apr 4, 2018
- Abate by
- May 7, 2018
- Penalty
- Initial $2,772 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.28(b)(3)(ii): (ii) Each employee is protected from tripping into or stepping into or through any hole that is less than 4 feet (1.2 m) above a lower level by covers or guardrail systems; a) a) On or about 11/30/17 on the roll grader system; employees picked out weeds and other debris from the sizing chain conveyor and were exposed to an unprotected fall of 21 feet when the area below this conveyor and the work platform was open. b) On or about 11/30/17 on the roll grader system; employees inspected product, picked weeds and removed stones at the intake end of the sizing chain and were exposed to an unprotected fall of 21 feet when the area below this conveyor was open. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1500
- — Z (S) $2772
1910.28 B01 I
- Issued
- Apr 4, 2018
- Abate by
- May 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following: Guardrail systems, safety net systems, or personal fall arrest systems: a) On or about 11/30/17 on the roll grader system; employees used a compressed air wand to clean in and around the discharge of # 5 hopper and were exposed to an unprotected fall of 5.5 feet into the hopper when the top perimeter (three sides) of the floor level hopper was open. b) On or about 11/30/17 on the roll grader system; employees used a compressed air wand to clean in and around the west side of hopper #4 and were exposed to an unprotected fall of 5.5 feet when height of the frame was between 25 - 16 inches from the work platform. c) On or about 11/30/17 on the roll grader system; employees used a compressed air wand to clean in and around the west side of hopper #3 and were exposed to an unprotected fall of 5.5 feet when the height of the frame was between 36 - 26 inches from the work platform. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C01
- Issued
- Apr 4, 2018
- Abate by
- May 17, 2018
- Penalty
- Initial $2,772 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a)On or about 12/01/17 throughout the facility; employees were involved in servicing and maintenance of the equipment, such as but no limited to greasing, cleaning, clearing jams on the roll topper, drag line, upper reel and were exposed to amputation hazards when the employer allowed the use of the emergency stop buttons as energy control. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1500
- — Z (S) $2772
1910.212 A03 II
- Issued
- Apr 4, 2018
- Abate by
- Jul 16, 2018
- Penalty
- Initial $3,880 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) On or about 11/30/17 on the outside roll grader system; employees were exposed to an amputation hazard while attempting to remove debris from the rotating rollers on the roll topper when the cover over the rollers was easily removable permitting access to the rollers. b) On or about 11/30/17 on the outside roll grader system: employees were exposed to an amputation hazard when the grease fittings on the west end of the roll topper rollers were exposed allowing access to the rotating rollers. c) On or about 11/30/17 on the outside roll grader system; employees were exposed to a caught between hazard when the rubbers fingers on the intake end of the cleaner were not guarded on either side allowing access to these rotating parts. d) On or about 03/29/18 on the conveyor for the roll grader system; employees were exposed to caught between hazard on the ingoing nip point of the bottom roller located at grade. e) On or about 03/29/18 on the drag line feeding the conveyor; employees were exposed to caught on hazards when the drag line flights feeding the conveyor were not guarded at a height of approximately 6 feet from grade. ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $3000
- — Z (S) $3880
1910.219 C04 I
- Issued
- Apr 4, 2018
- Abate by
- May 7, 2018
- Penalty
- Initial $2,217 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a) On or about 11/30/17 on the outside roll grader system; employees worked in and around the roll topper and sizing chain were exposed to caught in hazard when the rotating drive shaft of the roll toper, located at waist height on the north side of the work platform, was not guarded. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1250
- — Z (S) $2217
1910.219 C04 II
- Issued
- Apr 4, 2018
- Abate by
- May 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(4)(ii): The unused keyway(s) of projecting shaft end(s) were not filled up or covered: a) On or about 11/30/17 on the outside roll grader system; employees who work in and around the roll topper and sizing chain were exposed to caught in hazard when there was an open keyway on the rotating drive shaft of the roll toper, located at waist height on the north side of the work platform. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 F03
- Issued
- Apr 4, 2018
- Abate by
- May 7, 2018
- Penalty
- Initial $2,217 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven 7 feet or less above floors or platforms were not enclosed: a) On or about 11/30/17 on the outside roll grader system; employees who work in and around the roll topper and sizing chain were exposed to caught in hazard when the drive chain and sprockets located at waist height from the work platform were exposed and not guarded. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1250
- — Z (S) $2217
1910.144 A01 III
- Issued
- Apr 4, 2018
- Abate by
- May 17, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.144(a)(1)(iii): Emergency stop buttons or switches which letters or other markings appear, used for emergency stopping of machinery were not red. a) On or about 12/01/17 at the top of the stairs opposite the roll topper; employees were exposed to a minimal hazard when the large round shiny silver colored button in the upper left hand corner on the control panel was not labeled but appeared to be an emergency stop button. b) On or about 12/01/17 at the bottom of the roll topper; employees were exposed to minimal hazard when the large round dull color plastic button attached on the lower portion of the roll topper support leg was represented to be an emergency stop button and was not labeled or red in color. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 424480)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342799764.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.