On , OSHA opened a planned safety inspection of MANUEL REYES in 5624 BARRIQUE BLVD., MC KINNEY, TX 75070 (NAICS 238130). OSHA activity number 342800042.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Manuel Reyes — free Get an email when a new federal OSHA severe-injury report for Manuel Reyes is published. One employer, no account, unsubscribe in one click.
Establishment
MANUEL REYES
Site address
5624 BARRIQUE BLVD.
City
MC KINNEY
State
TX
ZIP
75070
Mailing
3620 UNIVERSITY DRIVE, ROWLETT, TX 75088
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

7 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 9, 2018
Abate by
Jan 29, 2018
Penalty
Initial $3,326 · Current $3,326
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:   (a) On or about November 28, 2017, employees installing cornices to a single family residential home located at 5924 Barrique Blvd, McKinney, TX.  At least one (1) employee was working from the ground doing various work operations and did not have on a hard hat.  The employees were exposed to head injuries where overhead hazard exists.
Recent events (1)
  • — Z (S) $3326

1926.102 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 9, 2018
Abate by
Jan 29, 2018
Penalty
Initial $3,326 · Current $3,326
29 CFR 1926.102(a)(1):   Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents:         (a) On or about November 28, 2017, employees installing cornices to a single family residential home located at 5924 Barrique Blvd, McKinney, TX.  Employees were doing cornice work while using nail guns. Employees were not wearing safety glasses and were exposed to eye injuries.
Recent events (1)
  • — Z (S) $3326

1926.405 G02 IV

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 9, 2018
Abate by
Jan 29, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws:    (a)  On or about November 28, 2017, employees installing cornices to a single family residential home located at 5924 Barrique Blvd, McKinney, TX.  Employees using a Jenny Air Compressor, Model K, Serial number G050416007 had a strain relief exposed them to electrical hazards.
Recent events (1)
  • — Z (S) $3880

1926.416 A01

Serious Gravity 10 2 instances 3 exposed
Issued
Jan 9, 2018
Abate by
Jan 29, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.416(a)(1):  No employer will permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by de energizing the circuit and grounding it or by guarding it effectively by insulation or other means:   (a) On or about November 28, 2017, employees installing cornices to a single family residential home located at 5924 Barrique Blvd, McKinney, TX.   Employees using an electrical cord that did not have a ground pin, exposing employees to an electrical hazard.
Recent events (1)
  • — Z (S) $0

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 9, 2018
Abate by
Jan 29, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level:   (a) On or about November 28, 2017, employees installing cornices to a single family residential home located at 5924 Barrique Blvd, McKinney, TX were exposed to fall hazards while working from a single pole scaffold.  Employees were not protected by the use of a personal fall arrest system or safety net system.
Recent events (1)
  • — Z (S) $3880

1926.1051 A

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 9, 2018
Abate by
Jan 16, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.1051(a): Stairway or ladder were not provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided:   (a) On or about November 28, 2017, employees installing cornices to a single family residential home located at 5924 Barrique Blvd, McKinney, TX.  Employees using a ten (10) step job made ladder that did not reach the work platform, exposing employees  fall hazards of approximately 10-feet to the ground level.
Recent events (1)
  • — Z (S) $3880

1926.1053 A08

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 9, 2018
Abate by
Jan 16, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(a)(8): A metal spreader or locking device were not provided on each stepladder to hold the front and back sections in an open position when the ladder is being used:   (a) On or about November 28, 2017, employees installing cornices to a single family residential home located at 5924 Barrique Blvd, McKinney, TX.  Employees using an 8-foot, Werner ladder with the spreaders closed, employees were exposed to a fall hazard.