Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MOEHNKE CUSTOM CABINETRY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MOEHNKE CUSTOM CABINETRY in 2210 W 2ND STREET, TAYLOR, TX 76574 (NAICS 337110). OSHA activity number 342801487.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Moehnke Custom Cabinetry — free Get an email when a new federal OSHA severe-injury report for Moehnke Custom Cabinetry is published. One employer, no account, unsubscribe in one click.
Site address
2210 W 2ND STREET
City
TAYLOR
State
TX
ZIP
76574
Mailing
203 COMMERCIAL DRIVE, TAYLOR, TX 76574
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
5
Ownership type
A

7 citations on file for this inspection.

1910.213 C01

Serious Gravity 5 2 instances 1 exposed
Issued
Dec 5, 2017
Abate by
Dec 11, 2017
Penalty
Initial $3,259 · Current $1,955 Reduced
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut.  On or about 30 November 2017, and at times prior thereto, employees used table saws to cut pieces of wood without the use of a blade guard, exposing the employees to an amputation hazard from being struck by the rotating blade. 1) A Delta Unisaw 10 Inch Tilting Arbor Saw located at 2210 West 2nd Street was missing the blade guard. 2) A Saw Stop Table Saw located at 203 Commercial Drive was missing the blade guard.
Recent events (2)
  • — I (S) $1955.4
  • — Z (S) $3259

1910.213 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 5, 2017
Abate by
Dec 11, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(2): Handfed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator.  On or about 30 November 2017, and at times prior thereto, employees used a Delta Unisaw 10 Inch Tilting Arbor Saw located at 2210 West 2nd Street to cut pieces of wood without the use of a spreader, exposing the employees to an amputation hazard from being struck by the rotating blade upon binding of the cut pieces of wood.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 C03

Serious Gravity 5 2 instances 1 exposed
Issued
Dec 5, 2017
Abate by
Dec 11, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator.  On or about 30 November 2017, and at times prior thereto, employees used table saws to cut pieces of wood without the use of an anti-kickback device, exposing the employees to an amputation hazard from being struck by the rotating blade. 1) A Delta Unisaw 10 Inch Tilting Arbor Saw located at 2210 West 2nd Street was missing the anti-kickback device. 2) A Saw Stop Table Saw located at 203 Commercial Drive was missing the anti-kickback device.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 P04

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 5, 2017
Abate by
Dec 11, 2017
Penalty
Initial $2,173 · Current $1,304 Reduced
29 CFR 1910.213(p)(4): Belt sanding machinery was not provided with a guard at each nip point where the sanding belt ran onto a pulley, to prevent the operator's hands or fingers from coming into contact with nip points.  On or about 30 November 2017, and at times prior thereto, an employee used a Ritter R911 Horizontal Edge Belt Sander on product without the guards in place, exposing the employee to an amputation hazard from being pulled into the ingoing pinch points.
Recent events (2)
  • — I (S) $1303.8
  • — Z (S) $2173

1910.242 B

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 5, 2017
Abate by
Dec 11, 2017
Penalty
Initial $1,630 · Current $978 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.  On or about 30 November 2017, and at times prior thereto, two employees used compressed air for cleaning purposes in which the air pressure measured at over 30 psi, exposing the employees to the hazard of being struck by the jet stream or foreign bodies in the eye(s).
Recent events (2)
  • — I (S) $978
  • — Z (S) $1630

1910.305 J03 I

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 5, 2017
Abate by
Dec 11, 2017
Penalty
Initial $1,630 · Current $978 Reduced
29 CFR 1910.305(j)(3)(i): Appliances had live parts normally exposed to employee contact.  On or about 30 November 2017, and at times prior thereto, the On/Off panel for the Ritter R911 Horizontal Edge Belt Sander was missing the cover, exposing employees to an electrical hazard of approximately 120 volts.
Recent events (2)
  • — I (S) $978
  • — Z (S) $1630

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 5, 2017
Abate by
Dec 11, 2017
Penalty
Initial $2,173 · Current $1,304 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the recognized hazard of being struck by fragments of plastic pipe due to the pipes potential for explosive shattering when used to transport compressed air.   On or about 30 November 2017, and at times prior thereto, a compressed air system installed within the wood shop located at 203 Commercial Drive was using Polyvinyl Chloride (PVC) piping while operating at approximately 120 psi. The plastic service line was being used for various machines and tools, and had multiple drops to quick connect outlets for air lines.   PVC pipe and fittings do not possess shatter resistant properties and the brittle PVC material can be broken or shattered by external forces and stress.  This pipe is designed for transmittal of liquids which do not possess the high amounts of stored energy present in compressed gases. This hazard has been recognized by manufacturers of PVC products, the Plastic Pipe Institute, the American National Standards Institute, and OSHA through an official Safety Hazard Information Bulletin dated May 20, 1988.
Recent events (2)
  • — I (S) $1303.8
  • — Z (S) $2173

View Moehnke Custom Cabinetry's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342801487.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.