Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OLDHAM LUMBER CO.,INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of OLDHAM LUMBER CO.,INC. in 8738 FORNEY ROAD, DALLAS, TX 75231 (NAICS 423310). OSHA activity number 342807278.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Oldham Lumber Co.,Inc. — free Get an email when a new federal OSHA severe-injury report for Oldham Lumber Co.,Inc. is published. One employer, no account, unsubscribe in one click.
Site address
8738 FORNEY ROAD
City
DALLAS
State
TX
ZIP
75231
Mailing
8738 FORNEY ROAD, DALLAS, TX 75231
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423310
Employees
49
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 29 exposed
Issued
Feb 14, 2018
Abate by
Mar 13, 2018
Penalty
Initial $9,054 · Current $4,527 Reduced

Hazardous substances 8390

OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees while working during the night hours without lighting around trucks and forklifts:    On or about December 4, 2017 and at times thereafter, employees working during the night hours with limited illumination were exposed to struck-by hazards while working around moving trucks and forklifts and to trip hazards while walking on walkways.
Recent events (2)
  • — I (S) $4527
  • — Z (S) $9054

1910.106 B02 II A

Deleted Serious Gravity 10 1 instance 29 exposed
Issued
Feb 14, 2018
Abate by
Mar 13, 2018
Penalty
Initial $9,054 · Current $0 Reduced
29 CFR 1910.106(b)(2)(ii)(a): The distance between any two flammable liquid storage tanks was less than 3 feet:  a) In the diesel fueling area of the Oldham Lumber Co., Inc. facility where two above ground steel storage tanks containing diesel were placed approximately twenty and one-quarter inches between them exposing employees to fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9054

1910.305 B01 I

Serious Gravity 10 1 instance 29 exposed
Issued
Feb 14, 2018
Abate by
Mar 13, 2018
Penalty
Initial $9,054 · Current $4,527 Reduced

Hazardous substances 8870

29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions:    (a) In the diesel fueling area of the Oldham Lumber Co., Inc. facility where an electrical junction box was damaged and the conductors were not protected from abrasion exposing employees to electrocution hazards.
Recent events (2)
  • — I (S) $4527
  • — Z (S) $9054

1910.303 G02 II

Serious Gravity 10 1 instance 29 exposed
Issued
Feb 14, 2018
Abate by
Mar 13, 2018
Penalty
Initial $0 · Current $0

Hazardous substances 8870

29 CFR 1910.303(g)(2)(ii): In locations where electric equipment was likely to be exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage:  a) In the Oldham Lumber Co., Inc. facility where an unprotected electrical outlet box located in a diesel refueling area was exposed to physical damage from trucks and forklifts and employees were exposed to electrocution hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 10 1 instance 29 exposed
Issued
Feb 14, 2018
Abate by
Mar 13, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a) In the diesel fueling area of the Oldham Lumber Co., Inc. facility where an electrical extension cord used to power a fluid pump used for dispensing diesel exhaust fluid had a damaged outer jacket exposing employees to electrical shock hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Other-than-serious 1 instance 29 exposed
Issued
Feb 14, 2018
Abate by
Mar 30, 2018
Penalty
Initial $9,054 · Current $4,527 Reduced

Hazardous substances 1810K107

29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:      a) In the diesel fueling area of the Oldham Lumber Co., Inc. facility where the employer did not have a written hazard communication program in place and employees dispensed diesel fuel on a daily basis that contained kerosene and naphthalene.
Recent events (2)
  • — I (O) $4527
  • — Z (S) $9054

View Oldham Lumber Co.,Inc.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342807278.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.