NAPLES, FL —
OSHA Inspection: VCC CONTRACTING LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of VCC CONTRACTING LLC in 760 PARK STREET, NAPLES, FL 34102 (NAICS 236220). OSHA activity number 342808482.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VCC CONTRACTING LLC
- Site address
- 760 PARK STREET
- City
- NAPLES
- State
- FL
- ZIP
- 34102
- Mailing
- 3811 AIRPORT RD N #102, NAPLES, FL 34105
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 35
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B01
- Issued
- May 29, 2018
- Abate by
- Jun 8, 2018
- Penalty
- Initial $9,054 · Current $5,435 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about November 30, 2018, at the above addressed jobsite, employees who performed fascia work on a new residential construction, from scaffolds that were not fully planked, were exposed to a fall hazard of approximately 22-feet to ground level.
Recent events (2)
- — I (S) $5435
- — Z (S) $9054
1926.451 G01
- Issued
- May 29, 2018
- Abate by
- Jun 8, 2018
- Penalty
- Initial $9,054 · Current $5,435 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: On or about November 30, 2017, at the north side of a new residential construction located at 760 Park Street, Naples, Florida 34102, employees who were not protected from falling with a means of fall protection system were exposed to a fall hazard of approximately 22-feet to ground level while performing fascia work.
Recent events (2)
- — I (S) $5435
- — Z (S) $9054
1926.452 G01
- Issued
- May 29, 2018
- Abate by
- Jun 8, 2018
- Penalty
- Initial $9,054 · Current $5,435 Reduced
General-duty citation text
29 CFR 1926.452(g)(1): Each bracket, except those for wooden bracket-form scaffolds, was not attached to the supporting formwork or structure by means of one or more of the following: nails; a metal stud attachment device; welding; hooking over a secured structural supporting member, with the form wales either bolted to the form or secured by snap ties or tie bolts extending through the form and securely anchored; or, for carpenters' bracket scaffolds only, by a bolt extending through to the opposite side of the structure's wall: On or about November 30, 2018, at the above addressed jobsite, employees were exposed to a fall hazard of approximately 22-feet to ground level while performing fascia work from scaffolds that were not properly secured to the structure.
Recent events (2)
- — I (S) $5435
- — Z (S) $9054
1926.1052 C01 II
- Issued
- May 29, 2018
- Penalty
- Initial $5,174 · Current $3,105 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: On or about November 30, 2018, at the above addressed jobsite, employees were exposed to a fall hazard of approximately 6-feet while using a stairway which was not protected with a stair-rail to gain access to the second floor of a new residential construction.
Recent events (2)