Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GEN BUILDING GROUP INC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of GEN BUILDING GROUP INC in 760 PARK ST, NAPLES, FL 34102 (NAICS 238130). OSHA activity number 342808631.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch GEN Building Group INC — free Get an email when a new federal OSHA severe-injury report for GEN Building Group INC is published. One employer, no account, unsubscribe in one click.
Site address
760 PARK ST
City
NAPLES
State
FL
ZIP
34102
Mailing
4245 HERITAGE CIR #207, NAPLES, FL 34116
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

8 citations on file for this inspection.

1926.451 B01

Serious Gravity 10 1 instance 5 exposed
Issued
May 29, 2018
Abate by
Jun 8, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):  On or about November 30, 2018, at the above addressed jobsite, employees who performed fascia work on a new residential construction from scaffolds that were not fully planked, were exposed to a fall hazard of approximately 22-feet to ground level.
Recent events (1)
  • — Z (S) $3880

1926.451 E01

Serious Gravity 10 1 instance 5 exposed
Issued
May 29, 2018
Abate by
Jun 8, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access:  On or about November 30, 2018, at the above addressed jobsite, employees were exposed to a fall hazard of approximately 22-feet while accessing scaffolds through a window sill of a second floor of a new residential construction.
Recent events (1)
  • — Z (S) $3880

1926.451 F06

Serious Gravity 10 1 instance 4 exposed
Issued
May 29, 2018
Abate by
Jun 8, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6):  On or about November 30, 2018, at the above addressed jobsite, employees were exposed to an electrical hazard while performing fascia work from scaffolds which were located approximately 3-feet from overhead power lines.
Recent events (1)
  • — Z (S) $3880

1926.451 F07

Serious Gravity 10 1 instance 5 exposed
Issued
May 29, 2018
Abate by
Jun 15, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person:  On or about November 30, 2018, at the above addressed jobsite, employees were exposed to a fall hazard of 22-feet while erecting, dismantling and moving  a carpenters' bracket scaffolds without a competent person, on a new residential construction.
Recent events (1)
  • — Z (S) $3880

1926.451 G01

Serious Gravity 10 1 instance 4 exposed
Issued
May 29, 2018
Abate by
Jun 8, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:  On or about November 30, 2017, at the north side of a new residential construction located at 760 Park Street, Naples, Florida 34102, employees who were not protected from falling with a means of fall protection system were exposed to a fall hazard of approximately 22-feet to ground level while performing fascia work.
Recent events (1)
  • — Z (S) $3880

1926.452 G01

Serious Gravity 10 1 instance 5 exposed
Issued
May 29, 2018
Abate by
Jun 8, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.452(g)(1): Each bracket, except those for wooden bracket-form scaffolds, was not attached to the supporting formwork or structure by means of one or more of the following: nails; a metal stud attachment device; welding; hooking over a secured structural supporting member, with the form wales either bolted to the form or secured by snap ties or tie bolts extending through the form and securely anchored; or, for carpenters' bracket scaffolds only, by a bolt extending through to the opposite side of the structure's wall:  On or about November 30, 2018, at the above addressed jobsite, employees were exposed to a fall hazard of approximately 22-feet to ground level while performing fascia work from scaffolds that were not properly secured to the structure.
Recent events (1)
  • — Z (S) $3880

1926.454 A02

Serious Gravity 10 1 instance 4 exposed
Issued
May 29, 2018
Abate by
Jun 8, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.454(a)(2): Employees have not received training in the correct procedures for dealing with electrical hazards and for erecting, maintaining, disassembling the fall protection systems and falling object protection systems being used:  On or about November 30, 2018, at the above addressed jobsite, the employer did not train the employees on the recognition of the electrical hazard while erecting scaffolds and performing fascia work on a new residential construction, approximately 3 feet away from overhead power lines.
Recent events (1)
  • — Z (S) $3880

1926.1052 C01 II

Serious Gravity 5 1 instance 5 exposed
Issued
May 29, 2018
Penalty
Initial $2,217 · Current $2,217
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:  On or about November 30, 2018, at the above addressed jobsite, employees were exposed to a fall hazard of approximately 6-feet while using a stairway which was not protected with a stair-rail to gain access to the second floor of a new residential construction.
Recent events (1)
  • — Z (S) $2217

View GEN Building Group INC's full OSHA safety record →