JANESVILLE, WI —
OSHA Inspection: DG DISTRIBUTION MIDWEST, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DG DISTRIBUTION MIDWEST, LLC in 101 INNOVATION DR., JANESVILLE, WI 53548 (NAICS 493110). OSHA activity number 342809480.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DG DISTRIBUTION MIDWEST, LLC
- Site address
- 101 INNOVATION DR.
- City
- JANESVILLE
- State
- WI
- ZIP
- 53548
- Mailing
- 101 INNOVATION DR., JANESVILLE, WI 53548
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 475
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Mar 23, 2018
- Abate by
- Apr 20, 2018
- Penalty
- Initial $12,195 · Current $12,195
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about December 5, 2017, and on dates prior, employee(s) had not utilized lockout/tagout procedures while performing inspection and cleaning work on spiral conveyors such as, but not limited to, the AmbaFlex Spiralveyor SV (Serial No. 60249-05).
Recent events (3)
- — F (S) $12195
- — C (S) $12195
- — Z (S) $12195
1910.147 D03
- Issued
- Mar 23, 2018
- Abate by
- Apr 20, 2018
- Penalty
- Initial $12,195 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): On or about December 5, 2017, and on dates prior, employee(s) were not using energy isolating devices to isolate spiral conveyors from energy source(s) prior to performing inspections and cleaning on this equipment. The list of spiral conveyors includes, but is not limited to, the AmbaFlex Spiralveyor SV (Serial No. 60249-05).
Recent events (3)
- — F (S) $0
- — C (S) $12195
- — Z (S) $12195
1910.147 D04 I
- Issued
- Mar 23, 2018
- Abate by
- Apr 20, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: On November 30, 2017, and on dates prior, authorized employees were not affixing lockout/tagout devices to energy isolating devices on spiral conveyors prior to performing servicing and maintenance activities such as, but not limited to, daily inspections and preventative maintenance.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at DG Distribution Midwest, LLC
View DG Distribution Midwest, LLC's full OSHA safety record →
More inspections in this industry (NAICS 493110)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342809480.