LANSDALE, PA —
OSHA Inspection: EPN CONSTRUCTION, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EPN CONSTRUCTION, LLC in PENN SQUARE N. CANNON AVE. AND W. SECOND ST., LANSDALE, PA 19446 (NAICS 238130). OSHA activity number 342811023.
Where did this inspection happen?
- Establishment
- EPN CONSTRUCTION, LLC
- Site address
- PENN SQUARE N. CANNON AVE. AND W. SECOND ST.
- City
- LANSDALE
- State
- PA
- ZIP
- 19446
- Mailing
- 314 3RD AVE., BEVERLY, NJ 08010
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $5174.00 · Current $5174.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Penn Square, Lots 21-30 - On or about October 25, 2017, Employees receiving trusses hoisted by a crane worked from the top plates of the third floor framing and were not protected from falling more than 6 feet to the next lower level. b) Penn Square, Lots 21-30 - On or about October 25, 2017, Employees walking/working on the exterior second floor decks were not protected from falling more than 6 feet to the ground. c) Penn Square, Lots 21-30 - On or about October 25, 2017, Employees framing the roof over the exterior second floor decks were not protected from falling more than 6 feet to the ground.
Recent events (1)
- — Z (S) $5174
1926.1053 B01
- Issued
- Penalty
- Initial $2956.00 · Current $2956.00
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. a) Construction site, rear of structure - On or about October 25, 2017, employees used a job made ladder that did not extend 3 feet above the landing surface to access a second floor deck. The ladder was not secured from displacement and no grasping device was provided.
Recent events (1)
- — Z (S) $2956
More inspections at EPN CONSTRUCTION, LLC
GLEN BURNIE, MD—2018-08-29 00:00:00
EPN CONSTRUCTION LLC
LAKEWOOD, NJ—2018-05-24 00:00:00
EPN CONSTRUCTION, LLC.
VILLAS, NJ—2018-05-03 00:00:00
EPN CONSTRUCTION LLC
CHESTER, MD—2018-04-23 00:00:00
EPN CONSTRUCTION LLC
PHOENIXVILLE, PA—2018-04-13 00:00:00
EPN CONSTRUCTION, LLC
View EPN CONSTRUCTION, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
ENCINITAS, CA—2026-07-13
LOU RIDDLE CONSTRUCTION
MERIDIAN, ID—2026-07-10
IDAHO HOMES CONSTRUCTION LLC
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
SLINGER, WI—2026-07-10
RAMIREZ HOME BUILDERS LLC
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342811023.