CORFU, NY —
OSHA Inspection: YANCEY'S FANCY INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of YANCEY'S FANCY INC. in 857 MAIN RD, CORFU, NY 14036 (NAICS 311513). OSHA activity number 342811346.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- YANCEY'S FANCY INC.
- Site address
- 857 MAIN RD
- City
- CORFU
- State
- NY
- ZIP
- 14036
- Mailing
- 857 MAIN RD, CORFU, NY 14036
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311513
- Employees
- 130
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.303 E01
- Issued
- Jan 8, 2018
- Abate by
- Jan 31, 2018
- Penalty
- Initial $3,742 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.303(e)(1)(ii): Electric equipment may not be used unless the following markings have been placed on the equipment: markings giving voltage, current, wattage, or other ratings as necessary: a) On or about 11/21/2017 in the motor control center (MCC); where the arc flash rating and personal protective equipment requirements were not marked on the all the electrical equipment in the MCC including motor disconnects and main service entrance equipment. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2500
- — Z (S) $3742
1910.37 B05
- Issued
- Jan 8, 2018
- Abate by
- Jan 31, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): a) On or about 11/21/2017 in the maintenance shop; where doors to the motor control center (MCC) room could be mistaken for an exit door, the doors were not identified. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C05 II
- Issued
- Jan 8, 2018
- Abate by
- Jan 31, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices were utilized for other purposes than controlling energy: a) On or about 11/21/2017 in the reverse osmosis room; where two lockout locks were used for locking air valves in the open/on position for process operations (no servicing or maintenance was being performed on the valves or downstream equipment). ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Yancey'S Fancy INC.
View Yancey'S Fancy INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311513)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342811346.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.