Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADAN CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ADAN CONSTRUCTION LLC in 1422 LAKELAND AVE, CINCINNATI, OH 45237 (NAICS 238160). OSHA activity number 342816766.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Adan Construction LLC — free Get an email when a new federal OSHA severe-injury report for Adan Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
1422 LAKELAND AVE
City
CINCINNATI
State
OH
ZIP
45237
Mailing
1714 MINION AVE, CINCINNATI, OH 45205
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

6 citations on file for this inspection.

1926.20 B02

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jan 25, 2018
Abate by
Feb 21, 2018
Penalty
Initial $3,880 · Current $0 Reduced
29 CFR 1926.20(b)(2): Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.  On Dec. 6, 2017, there were no frequent and regular inspections being performed by a competent person to ensure the jobsite, materials and equipment such as residential fall protection systems and/or devices were being maintained and utilized in a safe condition.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3880

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 25, 2018
Penalty
Initial $3,880 · Current $1,934 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.    Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.    On Dec. 6, 2017, located on the northeast side of a residential roof structure, an employee was observed performing roofing work while not utilizing a fall protection system. Potential fall heights were measured to be greater than 18 feet above the ground below.
Recent events (2)
  • — I (S) $1934
  • — Z (S) $3880

1926.503 B01

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 25, 2018
Abate by
Feb 21, 2018
Penalty
Initial $1,663 · Current $1,663
29 CFR 1926.503(b)(1): The employer shall verify compliance with paragraph (a) of this section by preparing a written certification record. The written certification record shall contain the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. If the employer relies on training conducted by another employer or completed prior to the effective date of this section, the certification record shall indicate the date the employer determined the prior training was adequate rather than the date of actual training.    The employer did not have written certification of fall protection training for an employee observed performing roofing work on a residential roof structure while not utilizing a fall protection system and exposed to potential fall heights in excess of 18 feet.
Recent events (2)
  • — I (S) $1663
  • — Z (S) $1663

1926.1053 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 25, 2018
Abate by
Feb 21, 2018
Penalty
Initial $3,880 · Current $2,203 Reduced
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.    On Dec. 6, 2017, located on the northeast side of a residential roof structure, an employee was observed using a 12 foot portable straight ladder to gain roof access. The ladder did not extend at least 3 feet above the upper landing surface and was not secured at the top.
Recent events (2)
  • — I (S) $2203
  • — Z (S) $3880

1926.1053 B05 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 25, 2018
Abate by
Feb 21, 2018
Penalty
Initial $3,880 · Current $0 Reduced
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders shall be used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support).    On Dec. 6, 2017, located on the northeast side of a residential roof structure, an employee was observed using a 16 foot portable extension ladder to gain roof access. The ladder was placed at an excessive angle (54 degrees) which is not equivalent to approximately one-quarter of the working length of the ladder (41 degrees).
Recent events (2)
  • — I (S) $0
  • — Z (S) $3880

1926.1053 B09

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 25, 2018
Abate by
Feb 21, 2018
Penalty
Initial $3,880 · Current $0 Reduced
29 CFR 1926.1053(b)(9): The area around the top and bottom of ladders shall be kept clear.    On Dec. 6, 2017, located on the northeast side of a residential roof structure, an employee was observed using a 12 foot portable straight ladder to gain roof access. The area at the bottom of the ladder was not kept clear and blocked by a 6x12 wooden timber, a bucket and waste roofing shingles.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3880

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342816766.