Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CABINETS BY S.L. ANDERSON LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CABINETS BY S.L. ANDERSON LLC in 3737 HWY 41, CECIL, GA 31627 (NAICS 337110). OSHA activity number 342821550.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cabinets by S.L. Anderson LLC — free Get an email when a new federal OSHA severe-injury report for Cabinets by S.L. Anderson LLC is published. One employer, no account, unsubscribe in one click.
Site address
3737 HWY 41
City
CECIL
State
GA
ZIP
31627
Mailing
P.O. BOX 125, CECIL, GA 31627
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
5
Ownership type
A

5 citations on file for this inspection.

1910.133 A01

Serious Gravity 1 2 instances 2 exposed
Issued
May 14, 2018
Abate by
Jun 8, 2018
Penalty
Initial $1,663 · Current $1,008 Reduced
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:     a)   In the cabinet facility: On or about November 15, 2017, and at times prior thereto, the employer did not ensure that eye/face protection was worn by employees while engaging a hand-held sander on a work table, and utilizing pneumatic pressure to clean off work areas.       b)   In the cabinet facility: On or about November 15, 2017, and at times prior thereto, the employer did not ensure that eye/face protection was worn by employees while engaging a hand-held sander on the floor, preparing furniture for painting.
Recent events (2)
  • — I (S) $1008
  • — Z (S) $1663

1910.212 A05

Serious Gravity 5 1 instance 3 exposed
Issued
May 14, 2018
Abate by
Jun 8, 2018
Penalty
Initial $2,772 · Current $1,000 Reduced
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:     a)   In the cabinet facility: On or about November 15, 2017, and at times prior thereto, employees were exposed to hazards not limited to amputation, in that a floor-based cooling fan contained openings of at least 2-in. X 4-in. as employees engaged the ON/OFF switch, and frequented adjacent areas while performing duties.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2772

1910.242 B

Serious Gravity 1 1 instance 1 exposed
Issued
May 14, 2018
Abate by
Jun 8, 2018
Penalty
Initial $1,663 · Current $1,000 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    a)    In the cabinet facility: On or about November 15, 2017, and at times prior thereto, the employer did not ensure employees utilizing compressed air for cleaning which was reduced to less than 30 p.s.i., thus exposing workers to flying-debris hazards not limited to wood chips.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1663

1910.303 C03 I

Serious Gravity 5 1 instance 4 exposed
Issued
May 14, 2018
Abate by
Jun 8, 2018
Penalty
Initial $2,217 · Current $1,000 Reduced
29 CFR 1910.303(c)(3)(i): All splices and joints and the free ends of the conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose:    a)   In the cabinet facility: On or about November 15, 2017, and at times prior thereto, employees were exposed to electrical hazards not limited to electric shock, in that a 240V conductor-splice entering a panel box was not effectively covered with insulation as employees engaged light switches while standing in close proximity.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2217

1910.305 D02

Serious Gravity 5 1 instance 4 exposed
Issued
May 14, 2018
Abate by
Jun 8, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(d)(2): Panelboards were not mounted in cabinets, cutout boxes, or enclosures designed for the purpose and were not dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons:  a)   In the cabinet facility: On or about November 15, 2017, and at times prior thereto, employees were exposed to electrical hazards not limited to electric shock, in that a 240V energized panel board did not include a dead front as employees engaged the equipment to turn facility lights ON/OFF.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Cabinets by S.L. Anderson LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342821550.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.