Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: SUMMIT BUILDERS GROUP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SUMMIT BUILDERS GROUP in 2840-2850 W. 32ND AVE., DENVER, CO 80211 (NAICS 236116). OSHA activity number 342824109.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Summit Builders Group for free Get an email when a new federal OSHA severe-injury report for Summit Builders Group is published. One employer, no account, unsubscribe in one click.
Site address
2840-2850 W. 32ND AVE.
City
DENVER
State
CO
ZIP
80211
Mailing
4154 S. PAGOSA ST., AURORA, CO 80013
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
6
Ownership type
Private (A)

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 23, 2018
Abate by
Apr 18, 2018
Penalty
Initial $2,772 · Current $1,800 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems:    (a)  Summit Builders Group, at 2840 to 2850 W. 32nd Ave., Denver, CO 80211:  On and before December 4, 2017, the exposing employer did not ensure that each employee engaged in residential construction activities 6 feet or more above lower levels was protected from fall hazards by guardrail systems, safety net systems, or personal fall arrest systems.  Employees were performing framing work on the third story (top deck) of a residential construction project without the use of fall protection.  This condition resulted in exposure to fall hazards of approximately 26 feet.
Recent events (2)
  • · I (S) $1800
  • · Z (S) $2772

1926.502 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 23, 2018
Abate by
Apr 18, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.502(b)(2):  Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches high:  (a)  Summit Builders Group, at 2840 to 2850 W. 32nd Ave., Denver, CO 80211:  On and before December 4, 2017, the exposing employer did not ensure that midrails or equivalent intermediate structure members were installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches high.  Employees were performing framing work on the third story (top deck) of a residential construction project where midrails were missing.  This condition resulted in exposure to fall hazards of approximately 26 feet.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342824109.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.