DENVER, CO ·
OSHA Inspection: SUMMIT BUILDERS GROUP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SUMMIT BUILDERS GROUP in 2840-2850 W. 32ND AVE., DENVER, CO 80211 (NAICS 236116). OSHA activity number 342824109.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUMMIT BUILDERS GROUP
- Site address
- 2840-2850 W. 32ND AVE.
- City
- DENVER
- State
- CO
- ZIP
- 80211
- Mailing
- 4154 S. PAGOSA ST., AURORA, CO 80013
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 6
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Mar 23, 2018
- Abate by
- Apr 18, 2018
- Penalty
- Initial $2,772 · Current $1,800 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems: (a) Summit Builders Group, at 2840 to 2850 W. 32nd Ave., Denver, CO 80211: On and before December 4, 2017, the exposing employer did not ensure that each employee engaged in residential construction activities 6 feet or more above lower levels was protected from fall hazards by guardrail systems, safety net systems, or personal fall arrest systems. Employees were performing framing work on the third story (top deck) of a residential construction project without the use of fall protection. This condition resulted in exposure to fall hazards of approximately 26 feet.
Recent events (2)
- · I (S) $1800
- · Z (S) $2772
1926.502 B02
- Issued
- Mar 23, 2018
- Abate by
- Apr 18, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches high: (a) Summit Builders Group, at 2840 to 2850 W. 32nd Ave., Denver, CO 80211: On and before December 4, 2017, the exposing employer did not ensure that midrails or equivalent intermediate structure members were installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches high. Employees were performing framing work on the third story (top deck) of a residential construction project where midrails were missing. This condition resulted in exposure to fall hazards of approximately 26 feet.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 236116)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342824109.