Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HAR REMODELING SERVICE

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of HAR REMODELING SERVICE in 5318 MONCLAIR PLACE, SARASOTA, FL 34231 (NAICS 236118). OSHA activity number 342837853.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch HAR Remodeling Service — free Get an email when a new federal OSHA severe-injury report for HAR Remodeling Service is published. One employer, no account, unsubscribe in one click.
Site address
5318 MONCLAIR PLACE
City
SARASOTA
State
FL
ZIP
34231
Mailing
2804 7TH STREET EAST, BRADENTON, FL 34208
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
2
Ownership type
A

8 citations on file for this inspection.

1926.304 H01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 22, 2018
Penalty
Initial $2,772 · Current $2,772
29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut:  a) For employees working at 5310 Montclair Place in Sarasota, on or about December 14, 2017. Employees were exposed to amputaion hazards when they were using a table saw to cut wood that was not guarded by a hood which enclosing the saw blade above the table.
Recent events (1)
  • — Z (S) $2772

1926.304 F

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 22, 2018
Abate by
Mar 6, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.304(f): Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Electrically driven equipment was not equipped with magnetic switches or other devices that will prevent automatic restarting of the machine after a power failure:  a) For employees working at 5310 Montclair Place in Sarasota, on or about December 14, 2017.  Employees were using a table saw to rip wood that did not have an anti restart device on the table saw.
Recent events (1)
  • — Z (S) $0

1926.304 F

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 22, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.304(f): Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator:  a) For employees working at 5310 Montclair Place in Sarasota, on or about December 14, 2017. Employees were using a table saw to rip wood that did not have a spreader installed on the table saw.
Recent events (1)
  • — Z (S) $0

1926.304 F

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 22, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.304(f): Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:  a) For employees working at 5310 Montclair Place in Sarasota, on or about December 14, 2017. Employees were using a table saw to rip wood that did not have non-kickback fingers installed on the table saw.
Recent events (1)
  • — Z (S) $0

1926.451 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 22, 2018
Abate by
Mar 6, 2018
Penalty
Initial $2,217 · Current $2,217
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation:  a) For employees working at 5310 Montclair Place in Sarasota, on or about December 14, 2017. The supported scaffold that was in use on the site did not bear on base plates, mud sills or adequate firm foundation. The employees were exposed to a struck by hazard.
Recent events (1)
  • — Z (S) $2217

1926.502 D21

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 22, 2018
Abate by
Mar 6, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service:  a) For employees working at 5310 Montclair Place in Sarasota, on or about December 14, 2017. The lifeline rope in use was cut and not removed from service.
Recent events (1)
  • — Z (S) $3880

1926.503 B01

Other-than-serious 1 instance 1 exposed
Issued
Feb 22, 2018
Abate by
Mar 6, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record.  a) For employees working at 5310 Montclair Place in Sarasota, on or about December 14, 2017. The employer did not certify that fall protection training was conducted.
Recent events (1)
  • — Z (O) $0

1926.404 B01

Other-than-serious 1 instance 2 exposed
Issued
Feb 22, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1): The Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.  a) For employees working at 5310 Montclair Place in Sarasota, on or about December 14, 2017. The employees were utilizing power tools that were supplied power through extension cords that were not GFCI protected. The employees were exposed to an electrical shock hazard while working on aluminum ladders.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342837853.