OSHA Inspection: BUREAU OF LAND MANAGEMENT, ALSEA FALLS REC. SITE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BUREAU OF LAND MANAGEMENT, ALSEA FALLS REC. SITE in SOUTH FORK ALSEA ACCESS RD, ALSEA, OR 97324 (NAICS 924120). OSHA activity number 342839685.

Watch Bureau OF Land Management, Alsea Falls REC. Site — free Get an email when a new federal OSHA severe-injury report for Bureau OF Land Management, Alsea Falls REC. Site is published. One employer, no account, unsubscribe in one click.
Site address
SOUTH FORK ALSEA ACCESS RD
City
ALSEA
State
OR
ZIP
97324
Mailing
1717 FABRY RD. SE, SALEM, OR 97306
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924120
Employees
5
Ownership type
D

7 citations on file for this inspection.

1910.23 D07

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.23(d)(7): Grab bars did not extend 42 inches (1.1m) above the access level or landing platforms served by the ladder.   (a) Employee(s) accessing the Werner- Attic Master ladder to gain access to the upper storage area did not have a grab bar to transition from the ladder to the landing platform in the storage area, exposing employee(s) to falls of 8.5 feet.
Recent events (1)
  • — Z (S) $0

1910.28 B03 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.28(b)(3)(i): The employer did not ensure each employee is protected from falling through any hole (including skylights) that is 4 feet (1.2 m) or more above a lower level by one or more of the following: covers, guardrail systems, travel restraint systems, or personal fall arrest systems, as required by sub-items A through D of this section.  or in the alternative  29 CFR 1910.28(b)(3)(iii): Each employee was not protected from falling into a stairway floor hole by a fixed guardrail system on all exposed sides, except at the stairway entrance:    (a) The 53" by 23" floor opening for access to the upper storage area was not guarded to prevent employees from falling 8.5 feet through the ladder way opening.
Recent events (1)
  • — Z (S) $0

1910.212 A05

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:   (a) Employee(s) are exposed to serious injuries from unguarded rotating fan blades.
Recent events (1)
  • — Z (S) $0

1910.29 B02

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.29(b)(2): Midrails, screens, mesh, intermediate vertical members, solid panels or equivalent intermediate members were not installed between the walking/working surface and the top edge of the guardrail system as follows when there is not a wall or a parapet that is at least 21 inches.    (a) Employee(s) were exposed to items falling from the upper storage area where only a top rail was installed.
Recent events (1)
  • — Z (O) $0

1910.303 B02

Other-than-serious 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a) The light fixture's electrical box, located in the upper storage, area was missing the knock-out exposing conductors.  (b) The 110 volt receptacle box, located in the shop area, was missing the knock-out exposing conductors.
Recent events (1)
  • — Z (O) $0

1910.305 G01 IV B

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables may not be used where run through holes in walls, ceilings or floors:  (a) The power cord of the Black & Decker 8" bench grinder was put through holes in the wall.
Recent events (1)
  • — Z (O) $0

1910.305 J01 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located within 8 feet of the floor had live parts exposed to employee contact:  (a) The unguarded light bulb, located 57" above the floor in the upper storage area, was exposed to breakage.
Recent events (1)
  • — Z (O) $0