ALSEA, OR ·
OSHA Inspection: BUREAU OF LAND MANAGEMENT, ALSEA FALLS REC. SITE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BUREAU OF LAND MANAGEMENT, ALSEA FALLS REC. SITE in SOUTH FORK ALSEA ACCESS RD, ALSEA, OR 97324 (NAICS 924120). OSHA activity number 342839685.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BUREAU OF LAND MANAGEMENT, ALSEA FALLS REC. SITE
- Site address
- SOUTH FORK ALSEA ACCESS RD
- City
- ALSEA
- State
- OR
- ZIP
- 97324
- Mailing
- 1717 FABRY RD. SE, SALEM, OR 97306
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 924120
- Employees
- 5
- Ownership type
- Federal government (D)
Citations
7 citations on file for this inspection.
1910.23 D07
- Issued
- Jan 19, 2018
- Abate by
- Feb 14, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(d)(7): Grab bars did not extend 42 inches (1.1m) above the access level or landing platforms served by the ladder. (a) Employee(s) accessing the Werner- Attic Master ladder to gain access to the upper storage area did not have a grab bar to transition from the ladder to the landing platform in the storage area, exposing employee(s) to falls of 8.5 feet.
Recent events (1)
- · Z (S) $0
1910.28 B03 I
- Issued
- Jan 19, 2018
- Abate by
- Feb 14, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(3)(i): The employer did not ensure each employee is protected from falling through any hole (including skylights) that is 4 feet (1.2 m) or more above a lower level by one or more of the following: covers, guardrail systems, travel restraint systems, or personal fall arrest systems, as required by sub-items A through D of this section. or in the alternative 29 CFR 1910.28(b)(3)(iii): Each employee was not protected from falling into a stairway floor hole by a fixed guardrail system on all exposed sides, except at the stairway entrance: (a) The 53" by 23" floor opening for access to the upper storage area was not guarded to prevent employees from falling 8.5 feet through the ladder way opening.
Recent events (1)
- · Z (S) $0
1910.212 A05
- Issued
- Jan 19, 2018
- Abate by
- Feb 14, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: (a) Employee(s) are exposed to serious injuries from unguarded rotating fan blades.
Recent events (1)
- · Z (S) $0
1910.29 B02
- Issued
- Jan 19, 2018
- Abate by
- Feb 14, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.29(b)(2): Midrails, screens, mesh, intermediate vertical members, solid panels or equivalent intermediate members were not installed between the walking/working surface and the top edge of the guardrail system as follows when there is not a wall or a parapet that is at least 21 inches. (a) Employee(s) were exposed to items falling from the upper storage area where only a top rail was installed.
Recent events (1)
- · Z (O) $0
1910.303 B02
- Issued
- Jan 19, 2018
- Abate by
- Feb 14, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) The light fixture's electrical box, located in the upper storage, area was missing the knock-out exposing conductors. (b) The 110 volt receptacle box, located in the shop area, was missing the knock-out exposing conductors.
Recent events (1)
- · Z (O) $0
1910.305 G01 IV B
- Issued
- Jan 19, 2018
- Abate by
- Feb 14, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables may not be used where run through holes in walls, ceilings or floors: (a) The power cord of the Black & Decker 8" bench grinder was put through holes in the wall.
Recent events (1)
- · Z (O) $0
1910.305 J01 I
- Issued
- Jan 19, 2018
- Abate by
- Feb 14, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located within 8 feet of the floor had live parts exposed to employee contact: (a) The unguarded light bulb, located 57" above the floor in the upper storage area, was exposed to breakage.
Recent events (1)
- · Z (O) $0
More inspections in this industry (NAICS 924120)
More inspections in OR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342839685.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.