Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TITLETOWN OIL CORP.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of TITLETOWN OIL CORP. in 1511 LAWRENCE DRIVE, DE PERE, WI 54115 (NAICS 447110). OSHA activity number 342842291.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Titletown OIL Corp. — free Get an email when a new federal OSHA severe-injury report for Titletown OIL Corp. is published. One employer, no account, unsubscribe in one click.
Establishment
TITLETOWN OIL CORP.
Site address
1511 LAWRENCE DRIVE
City
DE PERE
State
WI
ZIP
54115
Mailing
1275 GLORY ROAD, GREEN BAY, WI 54304
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
447110
Employees
16
Ownership type
A

3 citations on file for this inspection.

1910.1000 A02

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 23, 2018
Abate by
Apr 20, 2018
Penalty
Initial $11,641 · Current $6,985 Reduced
29 CFR 1910.1000(a)(2): Other substances -- 8-hour Time Weighted Averages. An employee's exposure to any substance in Table Z-1, the exposure limit of which is not preceded by a "C", shall not exceed the 8-hour Time Weighted Average given for that substance any 8-hour work shift of a 40-hour work week:    a) On December 13, 2017, a Maintenance Employee was exposed to 991% of the 8-hour Time Weighted Average Carbon Monoxide exposure limit while power washing the interior of the Car Wash located at 1511 Lawrence Drive, De Pere, WI with a gasoline fueled power washer. The 8-hour Time Weighted Average exposure limit for Carbon Monoxide is 50 ppm. The Maintenance Employee was exposed to a Carbon Monoxide 8-hour Time Weighted Average of 495 ppm over a 371 minute time period.
Recent events (2)
  • — I (S) $6984.6
  • — Z (S) $11641

1910.1000 E

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 23, 2018
Abate by
Apr 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1000(e): To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134:  a) A Maintenance Employee power washing the interior of a car wash with a gasoline fueled power washer did not place the power washer outside of the car wash or ensure enough fresh air was provided inside the car wash to keep the carbon monoxide levels at a safe concentration. The 8-hour Time Weighted Average exposure limit for Carbon Monoxide is 50 ppm.The Maintenance Employee was exposed to a Carbon Monoxide 8-hour Time Weighted Average of 495 ppm over a 371 minute time period.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H03 III

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 23, 2018
Abate by
Apr 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(3)(iii): Training. Employee training shall include, at least, the measures employees can take to protect themselves from these hazards, including specific procedures the employer has implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures, and personal protective equipment to be used:  a) The employer did not establish and implement work practices to minimize carbon monoxide exposure when power washing the interior of a car wash with a gasoline fueled power washer, nor train employees on the required work practices.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342842291.