OSHA Inspection: JRC DESIGN BUILD, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JRC DESIGN BUILD, INC. in 644 S. LINCOLN LN., ARLINGTON HEIGHTS, IL 60004 (NAICS 238130). OSHA activity number 342842366.

Watch JRC Design Build, INC. — free Get an email when a new federal OSHA severe-injury report for JRC Design Build, INC. is published. One employer, no account, unsubscribe in one click.
Site address
644 S. LINCOLN LN.
City
ARLINGTON HEIGHTS
State
IL
ZIP
60004
Mailing
1275 DAVIS, ARLINGTON HEIGHTS, IL 60005
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $3696.00 · Current $2000.00 Reduced
29 CFR 1926.102(a)(1):  Eye and face protective equipment was not used when machines or operations presented potential eye or face injury:      a) On December 19, 2017, an employee was using a pneumatic nail gun without protective eye equipment while performing carpentry work.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3696

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $5174.00 · Current $3000.00 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:       a)  On December 19, 2017, employees were exposed to fall hazards of approximately 17.6 feet while performing carpentry work.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5174

1926.1053 B01

Serious Gravity 5 2 instances 4 exposed
Issued
Penalty
Initial $3696.00 · Current $2000.00 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:      a)  On December 19, 2017, the employer provided two extension ladders used by employees to gain access to the roof and did not have the side rails extended at least 3 feet above the surface.