Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RK STEEL, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RK STEEL, INC in 1222 N. 6TH, FREDONIA, KS 66736 (NAICS 332312). OSHA activity number 342844115.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RK Steel, INC — free Get an email when a new federal OSHA severe-injury report for RK Steel, INC is published. One employer, no account, unsubscribe in one click.
Establishment
RK STEEL, INC
Site address
1222 N. 6TH
City
FREDONIA
State
KS
ZIP
66736
Mailing
1222 N. 6TH, FREDONIA, KS 66736
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
51
Ownership type
A

3 citations on file for this inspection.

1910.212 B

Other-than-serious 1 instance 4 exposed
Issued
Feb 13, 2018
Penalty
Initial $6,596 · Current $4,617 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    Employees engaged in material drilling procedures, to include but not limited to, steel pipe used in the handrail manufacturing process were exposed to struck-by hazards in that the Jet Drill Press, Model JDP-15MF Serial number 15064052, was not securely anchored to the floor near the assembly area for the handrail.
Recent events (2)
  • — I (O) $4617.2
  • — Z (S) $6596

1910.147 C04 II

Serious Gravity 5 5 instances 2 exposed
Issued
Feb 13, 2018
Abate by
Mar 30, 2018
Penalty
Initial $6,467 · Current $4,527 Reduced
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy:  Employees engaged in Lock out Tag out procedures were exposed to, but not limited to, struck-by and caught in between hazards in that specific procedures were not developed for the following machinery that clearly and specifically outlined the techniques to be utilized for the control of hazardous energy:  A.) The Paddinghaus Saw in the drill bay, procedures are illegible, they do not identify specific sources of energy or individual steps to complete lockout.  B.) The Paddinghaus PDC 1100 in the drill bay, procedures are illegible, they do not indicate sources of energy or individual steps to be taken to complete lockout.  C.) Miller Welders W1-W4 in the fab shop, procedures do not identify location of circuit breakers and do not state how to purge gas regulator lines to complete lockout.  D.) West HE&M Saw in the fab shop, procedures do not identify means to release stored energy to complete lockout.  E.)  New HE&M Saw in the fab shop, procedures do not identify means to release stored energy to complete lockout.
Recent events (2)
  • — I (S) $4526.9
  • — Z (S) $6467

1910.147 C06 II

Serious Gravity 5 9 instances 2 exposed
Issued
Feb 13, 2018
Abate by
Mar 12, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection:  Employees engaged in, but not limited to maintenance activities, were exposed to struck-by, caught in, and electrical hazards in that the periodic inspection for energy control procedures did not contain the following information in the following conditions:  A.) Air Compressors, compressor was not identified, employees included were not identified, and person performing the audit was not identified.  B.) Mig Welder, individual welders were not identified, employees included were not identified, and person performing the audit was not identified.  C.) Plasma Torch, employees included were not identified, and person performing the audit was not identified.  D.) North HE&M Saw, employees included were not identified, and person performing the audit was not identified.  E.) South HE&M Saw, employees included were not identified, and person performing the audit was not identified.  F.) Multihead Drill Press, employees included were not identified, and person performing the audit was not identified.  H.) Peddinghaus Saw, employees included were not identified, and person performing the audit was not identified.  I.) Peddinghaus PDC 1100, employees included were not identified, and person performing the audit was not identified.  J.) Peddinghaus Angle Master, employees included were not identified, and person performing the audit was not identified.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View RK Steel, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342844115.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.