OSHA Inspection: HAMMER HAAG STEEL, INC.

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of HAMMER HAAG STEEL, INC. in 12707 US HWY 19 NORTH, CLEARWATER, FL 33764 (NAICS 332312). OSHA activity number 342845377.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hammer Haag Steel, INC. — free Get an email when a new federal OSHA severe-injury report for Hammer Haag Steel, INC. is published. One employer, no account, unsubscribe in one click.
Site address
12707 US HWY 19 NORTH
City
CLEARWATER
State
FL
ZIP
33764
Mailing
12707 US HWY 19 N, CLEARWATER, FL 33764
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
45
Ownership type
A

2 citations on file for this inspection.

1910.134 E01

Repeat 1 instance 1 exposed
Issued
Mar 7, 2018
Penalty
Initial $2,587 · Current $2,587
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:(a) (LOCATION) (IDENTIFY SPECIFIC OPERATION/CONDITION) (DESCRIBE HAZARD) Note:  The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.  a. Abrasive blasting enclosure - The employer did not provide respirator medical evaluations when employee(s) were required to use a RPB Nova 2000 supplied air respirator during abrasive blasting operations. Violation discovered on or about December 21, 2017.  Hammer Haag Steel, Inc. was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1910.134(e)(1), which was contained in OSHA inspection number 1223513 citation number 1, item number 1-C and was affirmed as a final order on 10/16/2017, with respect to a workplace located at 12707 US Hwy 19 North, Clearwater, FL 33764.
Recent events (1)
  • — Z (R) $2587

1910.134 I01 II

Repeat 1 instance 1 exposed
Issued
Mar 7, 2018
Penalty
Initial $258 · Current $258
29 CFR 1910.134(i)(1)(ii): Breathing air did not meet requirements for Grade D breathing air as described in the ANSI/Compressed Gas Association Commodity Specification G-7.1-1989:  a. At the site- The employer did not test the breathing air to ensure the compressed breathing air supplied by the RPB Nova 2000 supplied air respirator system used with the Ingersol Rand air compressor system met at least Grade D breathing air quality. Violation discovered on or about December 21, 2017.  Hammer Haag Steel, Inc. was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1910.134(i)(1)(ii), which was contained in OSHA inspection number 1223513 citation number 1, item number 2-A and was affirmed as a final order on 10/16/2017, with respect to a workplace located at 12707 US Hwy 19 North, Clearwater, FL 33764.