Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HIX CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HIX CORPORATION in 1201 E. 27TH TERR., PITTSBURG, KS 66762 (NAICS 333249). OSHA activity number 342845625.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch HIX Corporation — free Get an email when a new federal OSHA severe-injury report for HIX Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
HIX CORPORATION
Site address
1201 E. 27TH TERR.
City
PITTSBURG
State
KS
ZIP
66762
Mailing
1201 E. 27TH TERR., PITTSBURG, KS 66762
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333249
Employees
59
Ownership type
A

6 citations on file for this inspection.

1910.36 D01

Serious Gravity 5 6 instances 40 exposed
Issued
Apr 10, 2018
Abate by
May 4, 2018
Penalty
Initial $6,467 · Current $4,527 Reduced
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  Employees engaged in daily shop activities, to include but not limited to the dryer area, were exposed to fire hazards in that the egress doors contained two locking mechanisms that were not unlocked at all times of employee occupancy.
Recent events (2)
  • — I (S) $4526.9
  • — Z (S) $6467

1910.37 A01

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 10, 2018
Abate by
May 4, 2018
Penalty
Initial $3,880 · Current $2,716 Reduced
29 CFR 1910.37(a)(1): Exit routes shall not have flammable, explosive, combustible gases or flammable furnishings stored in the exit route.  Employees engaged in daily shop activities in and around the dryer area were exposed to fire hazards in that propane was allowed to be stored immediately next to the egress door that serves this area.
Recent events (2)
  • — I (S) $2716
  • — Z (S) $3880

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 10, 2018
Abate by
May 4, 2018
Penalty
Initial $5,174 · Current $3,622 Reduced
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.     Employees engaged in material cutting and drilling activities at the following pieces of equipment in the machine shop and wood shop were exposed to caught-in and amputation hazards in that:  a)  WF Well horizontal band saw, model number AC-7 SN 478, the unused portion of the blade was not guarded  b)  Drill press model UNK SN 31-5396, the bit and chuck were not guarded
Recent events (2)
  • — I (S) $3621.8
  • — Z (S) $5174

1910.303 B02

Serious Gravity 1 2 instances 15 exposed
Issued
Apr 10, 2018
Abate by
May 4, 2018
Penalty
Initial $3,880 · Current $2,716 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Employees engaged in the following activities in the following locations were exposed to electrical shock hazard in that electrical utilization equipment was not installed in accordance with the manufacture listing and labeling:  A.  The pendant box in the CFE Food Press area was not properly attached and secured to the structure of the rack and was allowed to hang from the wires.  B.  The pendant box in the engineering cubicle was not listed and labeled for use as a pendant box.
Recent events (2)
  • — I (S) $2716
  • — Z (S) $3880

1910.303 F02

Serious Gravity 1 2 instances 10 exposed
Issued
Apr 10, 2018
Abate by
May 4, 2018
Penalty
Initial $3,880 · Current $2,716 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  Employees engaged in utilizing electrical equipment in and around the engineering cubicles were exposed to electrical shock hazards in that the overcurrent devices for the two panels adjacent to the engineering cubicle were not marked to indicate its purpose.
Recent events (2)
  • — I (S) $2716
  • — Z (S) $3880

1910.303 G01

Serious Gravity 1 2 instances 10 exposed
Issued
Apr 10, 2018
Abate by
May 4, 2018
Penalty
Initial $3,880 · Current $2,716 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  Employees engaged in utilization of electrical equipment in the shop area, to include but not limited to the engineering cubicle and adjacent area, were exposed to shock hazards in that there was not sufficient access around the two electrical panels that serve this area of the facility.
Recent events (2)
  • — I (S) $2716
  • — Z (S) $3880

View HIX Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342845625.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.