Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RECTORSEAL, LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of RECTORSEAL, LLC in 1244 DAVOL STREET, FALL RIVER, MA 02720 (NAICS 333415). OSHA activity number 342851714.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rectorseal, LLC — free Get an email when a new federal OSHA severe-injury report for Rectorseal, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
RECTORSEAL, LLC
Site address
1244 DAVOL STREET
City
FALL RIVER
State
MA
ZIP
02720
Mailing
1244 DAVOL STREET, FALL RIVER, MA 02720
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333415
Employees
60
Ownership type
A

3 citations on file for this inspection.

1910.160 B01

Serious Gravity 5 3 instances 40 exposed
Issued
Apr 25, 2018
Abate by
Jun 14, 2018
Penalty
Initial $5,174 · Current $3,104 Reduced
29 CFR 1910.160(b)(1): Fixed extinguishing system components and agents were not designed and approved for use on the specific fire hazards they were expected to control or extinguish:    Location: Chemical Room    While mixing aluminum and calcium formate, an explosion occurred, and automatic water sprinklers were activated;  water is not approved as a fire suppressant for fires that would be expected to result from aluminum dust explosions.
Recent events (2)
  • — I (S) $3104.4
  • — Z (S) $5174

1910.305 G02 III

Serious Gravity 5 3 instances 40 exposed
Issued
Apr 25, 2018
Abate by
Jun 14, 2018
Penalty
Initial $5,174 · Current $3,104 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    Location: Chemical Room    1) Flexible cord attached to large Stokes 900-525-2(R) Rotary Tablet Press was not connected to a fitting so that tension would not be transmitted to terminal joint.  2) Flexible cord attached to foot pedal on Mateer powder filler was not connected to a fitting so that tension would not be transmitted to joints or terminal screws  3)Flexible cords to Hobart mixer and Con Air WOR-TEX Coarse Grinder  Granulator shutoffs were not connected to a fitting so that tension would not be transmitted to joints or terminal screws
Recent events (2)
  • — I (S) $3104.4
  • — Z (S) $5174

1910.1200 H03 II

Serious Gravity 5 6 instances 10 exposed
Issued
Apr 25, 2018
Abate by
Jun 14, 2018
Penalty
Initial $4,398 · Current $2,639 Reduced
29 CFR 1910.1200(h)(3)(ii): Employee training did not include the physical and health hazards of the chemicals in the work area:    Location: Chemical Area    The employer did not inform all employees working in the chemical room of the severity of the explosions that could result from mixing powders and dusts, some of which are potentially combustible, including aluminum.
Recent events (2)
  • — I (S) $2638.8
  • — Z (S) $4398

View Rectorseal, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342851714.