CALDWELL, OH —
OSHA Inspection: MAGNUM MAGNETICS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MAGNUM MAGNETICS in 17289 INDUSTRIAL HIGHWAY, CALDWELL, OH 43724 (NAICS 332999). OSHA activity number 342861374.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAGNUM MAGNETICS
- Site address
- 17289 INDUSTRIAL HIGHWAY
- City
- CALDWELL
- State
- OH
- ZIP
- 43724
- Mailing
- 801 MASONIC PARK RD, MARIETTA, OH 45750
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 80
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Apr 23, 2018
- Penalty
- Initial $11,641 · Current $11,641
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. a. At the Caldwell facility in the mill area, the specific lock out procedures for the granulators did not include the specific steps for blocking the blades from free flowing while maintenance or servicing activities were performed. b. At the Caldwell facility in the mill area, the specific lock out procedures for the granulators did not address how employees would ensure that the blades were no longer moving prior to opening the hood of the granulator to perform maintenance or servicing activities.
Recent events (1)
- — Z (S) $11641
1910.147 C06 II
- Issued
- Apr 23, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection: a. At the site, the employer did not certify that lockout procedures for the granulators was performed at least annually.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 332999)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342861374.