BROOKLYN, NY —
OSHA Inspection: M P & L METAL INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of M P & L METAL INC. in 223 MANHATTAN AVENUE, BROOKLYN, NY 11206 (NAICS 238120). OSHA activity number 342861945.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M P & L METAL INC.
- Site address
- 223 MANHATTAN AVENUE
- City
- BROOKLYN
- State
- NY
- ZIP
- 11206
- Mailing
- 1560 TROY AVE, BROOKLYN, NY 11203
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.760 A01
- Issued
- Jan 12, 2018
- Abate by
- Jan 19, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems. Location: a) On second floor of the building On or about 07/18/17, employees were installing steel decking on the second floor of the building, and were exposed to falling approximately 17 feet from second floor to ground level.
Recent events (1)
- — Z (S) $3880
1926.1051 A
- Issued
- Jan 12, 2018
- Abate by
- Jan 19, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided. Location: a) On the first floor of the jobsite: On or about 07/18/17, employees used the top step of an 8 feet A-frame ladder to climb to the top of the steel beam on the second floor level. The top of the steel beam was approximately 3 feet above the top of the ladder.
Recent events (1)
- — Z (S) $3880
1926.1053 B13
- Issued
- Jan 12, 2018
- Abate by
- Jan 19, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step. Location: a) On the first floor of the jobsite: On or about 07/18/17, employees used the top step of an 8 feet A-frame ladder to climb to the top of the steel beam on the second floor level. The top of the steel beam was approximately 3 feet above the top of the ladder.
Recent events (1)
- — Z (S) $0
1926.1053 B04
- Issued
- Jan 12, 2018
- Abate by
- Jan 25, 2018
- Penalty
- Initial $2,217 · Current $2,217
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed. Location: a) On ground level on the northeast side of the job site: On or about 07/18/17, employees used an 8 ft. A-Frame Ladder as a lean against ladder to access the first floor work area.
Recent events (1)
- — Z (S) $2217
1926.1053 B16
- Issued
- Jan 12, 2018
- Abate by
- Jan 25, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired. As reference in 29 CFR 1926.452(k)(2) Location: a) On the ground floor on the northeast side of the jobsite: On or about 07/18/17, employees used a damaged 8 ft. A-Frame Ladder to access the first floor work area. the Ladder was missing a rung.
Recent events (1)
- — Z (S) $0
More inspections at M P & L Metal INC.
View M P & L Metal INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238120)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342861945.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.