CHEEKTOWAGA, NY —
OSHA Inspection: TECTRAN MANUFACTURING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TECTRAN MANUFACTURING, INC. in 2345 WALDEN AVENUE SUITE 100, CHEEKTOWAGA, NY 14225 (NAICS 336340). OSHA activity number 342862158.
Where did this inspection happen?
- Establishment
- TECTRAN MANUFACTURING, INC.
- Site address
- 2345 WALDEN AVENUE SUITE 100
- City
- CHEEKTOWAGA
- State
- NY
- ZIP
- 14225
- Mailing
- 2345 WALDEN AVENUE SUITE 100, CHEEKTOWAGA, NY 14225
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336340
- Employees
- 130
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $6652.00 · Current $3600.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 01/04/18, throughout establishment, employer did not conduct periodic inspections of the Lockout/Tagout procedures for machines such as, but not limited to: the carrousel. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $3600
- — C (S) $6652
- — Z (S) $6652
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $6652.00 · Current $3600.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about, 01/04/17, in the power cable area, employees were exposed to caught-by hazards when wrapping wires together on the AirPower Line in close proximity of the cylinder that rotates with a protruding latch. b) On or about, 01/04/17, in the power cable area, employees were exposed to rotating parts when they were operating the Swing Blade Wire Stripper (SB1A) with the guard off. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $3600
- — C (S) $6652
- — Z (S) $6652
More inspections in this industry (NAICS 336340)
WHITE CITY, OR—2026-02-27
317743422 - BRONSON INVESTMENTS INC
CLOVERDALE, CA—2026-02-03
INDIAN HEAD INDUSTRIES, INC.
FOWLERVILLE, MI—2025-12-30
ZF ACTIVE SAFETY US
ROCKFORD, IL—2025-12-23
ROCKFORD BRAKE MANUFACTURING, INC.
GEORGETOWN, KY—2025-12-16
68659 - YS PRECISION STAMPING INC
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342862158.