Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: TEKNOL INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TEKNOL INC. in 5751 N. WEBSTER ST., DAYTON, OH 45414 (NAICS 325998). OSHA activity number 342865565.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Teknol INC. for free Get an email when a new federal OSHA severe-injury report for Teknol INC. is published. One employer, no account, unsubscribe in one click.
Establishment
TEKNOL INC.
Site address
5751 N. WEBSTER ST.
City
DAYTON
State
OH
ZIP
45414
Mailing
P.O. BOX 14387, DAYTON, OH 45414
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325998
Employees
64
Ownership type
Private (A)

4 citations on file for this inspection.

1910.132 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 19, 2018
Abate by
Feb 23, 2018
Penalty
Initial $3,880 · Current $1,940 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):    The employer's hazard assessment for the Cherry Burrell Piston Filler dated January 22, 2016 was inadequate in that it did not address hazards associated with fire.
Recent events (2)
  • · I (S) $1940
  • · Z (S) $3880

1910.132 D02

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 19, 2018
Abate by
Feb 23, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed:    The employer did not certify that a hazard assessment had been performed for the Primer Filler position.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 19, 2018
Penalty
Initial $4,850 · Current $2,425 Reduced
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    The employer did not ensure new employees were provided hazard communication training prior to exposure to organic solvents such as methyl ethyl ketone and toluene (flammable).
Recent events (2)
  • · I (S) $2425
  • · Z (S) $4850

1910.157 G02

Other-than-serious 1 instance 2 exposed
Issued
Jan 19, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:    The employer did not provide fire extinguisher training to employees upon initial assignment.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Teknol INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342865565.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.