WESLEY CHAPEL, FL —
OSHA Inspection: AZUAY CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AZUAY CONSTRUCTION, INC. in 8121 ROMA DUNE DR., WESLEY CHAPEL, FL 33543 (NAICS 238160). OSHA activity number 342866118.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AZUAY CONSTRUCTION, INC.
- Site address
- 8121 ROMA DUNE DR.
- City
- WESLEY CHAPEL
- State
- FL
- ZIP
- 33543
- Mailing
- 274 JOCELYN DR., DAVENPORT, FL 33897
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Feb 26, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) 8121 Roma Dune Dr. - Employees in the process of decking the 5 in 12 slope (vertical to horizontal) roof, were exposed to fall hazards up to 18'9", in that, fall protection equipment was not installed or utilized, observed on or about 01/05/2018.
Recent events (1)
- — Z (S) $3880
1926.1053 B01
- Issued
- Feb 26, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) 8121 Roma Dune Dr. - Employees were exposed to a 9'4" fall hazard, in that, the extension ladder did not extend 3 foot above the roof edge, observed on or about 01/05/2018.
Recent events (1)
- — Z (S) $3880
1926.503 B01
- Issued
- Feb 26, 2018
- Abate by
- Apr 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. (a) The employer does not have fall protection training certification for employees, observed on or about 01/05/2018.
Recent events (1)
- — Z (O) $0
More inspections at Azuay Construction, INC.
View Azuay Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342866118.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.