TERRELL, TX —
OSHA Inspection: STEELWAY INTERNATIONAL, L.L.C.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of STEELWAY INTERNATIONAL, L.L.C. in 2990 TEM TEX BLVD, TERRELL, TX 75160 (NAICS 332312). OSHA activity number 342867934.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STEELWAY INTERNATIONAL, L.L.C.
- Site address
- 2990 TEM TEX BLVD
- City
- TERRELL
- State
- TX
- ZIP
- 75160
- Mailing
- 2990 TEM TEX BLVD, TERRELL, TX 75160
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 38
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.95 C01
- Issued
- Mar 30, 2018
- Abate by
- May 16, 2018
- Penalty
- Initial $7,114 · Current $3,557 Reduced
8111
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: The employer did not administer a hearing conservation program for employees exposed to noise that exceeded an 8-hour time-weighted average (TWA) of 85 dBA: (a) In the truss department, a band saw operator was exposed to noise levels at 68.72% of the permissible 8-hour TWA (90 dBA). The equivalent dBA level of 68.72% is approximately 87.2 dBA. Sampling was performed for 480 minutes during one shift. (b) In the truss department, a fabricator was exposed to noise levels at 103.8% of the permissible 8-hour TWA (90 dBA). The equivalent dBA level of 103.8% is approximately 90.2 dBA. Sampling was performed for 425 minutes during one shift. Zero exposure was assumed for the unsampled period of 55 minutes. (c) In the truss department, a fabricator was exposed to noise levels at 126.5% of the permissible 8-hour TWA (90 dBA). The equivalent dBA level of 126.5% is approximately 91.6 dBA. Sampling was performed for 415 minutes during one shift. Zero exposure was assumed for the unsampled period of 65 minutes.
Recent events (2)
- — I (O) $3557
- — Z (S) $7114
More inspections at Steelway International, L.L.C.
View Steelway International, L.L.C.'s full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342867934.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.