OSHA Inspection: RED NOLAND CADILLAC, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RED NOLAND CADILLAC, INC. in 990 MOTOR CITY DR, COLORADO SPRINGS, CO 80905 (NAICS 811111). OSHA activity number 342871407.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RED Noland Cadillac, INC. — free Get an email when a new federal OSHA severe-injury report for RED Noland Cadillac, INC. is published. One employer, no account, unsubscribe in one click.
Site address
990 MOTOR CITY DR
City
COLORADO SPRINGS
State
CO
ZIP
80905
Mailing
990 MOTOR CITY DR, COLORADO SPRINGS, CO 80905
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
18
Ownership type
A

2 citations on file for this inspection.

1910.242 B

Other-than-serious 1 instance 1 exposed
Issued
Jan 29, 2018
Penalty
Initial $3,298 · Current $0 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:     (a) On or about January 10, 2018, and at times prior, the employer did not ensure that compressed air used for cleaning purposes was reduced to less than 30 p.s.i.. Employees cleaning and drying tools/parts were exposed to air injection hazards in that a compressed air nozzle located by auto lift #2 was observed with a tip that allowed 113 PSI air pressure.         Abatement Note: Abatement certification is not required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3298

1910.305 G02 III

Other-than-serious 1 instance 2 exposed
Issued
Jan 29, 2018
Abate by
Feb 23, 2018
Penalty
Initial $5,174 · Current $4,500 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    (a) On or about January 10, 2018, and at times prior, the employer did not ensure that flexible cords and cables were connected to devices and fittings so that strain relief was provided to prevent pull from being directly transmitted to joints or terminal screws. Employees were exposed to contact with electrical hazards in that a LANDA SEA 4-2000 pressure washer located in the detailing area was observed with signs of strain at the plug.    Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $4500
  • — Z (S) $5174

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342871407.