CONNELLSVILLE, PA ·
OSHA Inspection: BELLA ENTERPRISES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BELLA ENTERPRISES, INC. in 3120 RICHEY ROAD, CONNELLSVILLE, PA 15425 (NAICS 237110). OSHA activity number 342871860.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BELLA ENTERPRISES, INC.
- Site address
- 3120 RICHEY ROAD
- City
- CONNELLSVILLE
- State
- PA
- ZIP
- 15425
- Mailing
- 1446 SMITH TOWNSHIP STATE ROAD BUILDING 1, BURGETTSTOWN, PA 15021
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 12
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1926.651 C02
- Issued
- Feb 13, 2018
- Abate by
- Feb 26, 2018
- Penalty
- Initial $5,174 · Current $3,867 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) Jobsite, Area of 3120 Richey Road, Connellsville, PA 15425: On or before January 9, 2018, an employee was working within a 6 foot 5 inch trench without a ladder for safe access and egress.
Recent events (2)
- · I (S) $3867
- · Z (S) $5174
1926.651 K02
- Issued
- Feb 13, 2018
- Abate by
- Feb 26, 2018
- Penalty
- Initial $5,174 · Current $3,867 Reduced
General-duty citation text
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employee(s) was/were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety: a) Jobsite, Area of 3120 Richey Road, Connellsville, PA 15425: On or before January 9, 2018, work was progressing through an increase in grade which created trench collapse hazards. The competent person did not ensure protection was provided when the trench deepened.
Recent events (2)
- · I (S) $3867
- · Z (S) $5174
1926.652 A01
- Issued
- Feb 13, 2018
- Abate by
- Feb 26, 2018
- Penalty
- Initial $5,174 · Current $3,867 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c): a) Jobsite, Area of 3120 Richey Road, Connellsville, PA 15425: On or before January 9, 2018, an employee was exposed to trench collapse hazards while working at an unprotected depth in excess of 6 feet 5 inches.
Recent events (2)
- · I (S) $3867
- · Z (S) $5174
1926.651 J02
- Issued
- Feb 13, 2018
- Abate by
- Feb 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary: a) Jobsite, Area of 3120 Richey Road, Connellsville, PA 15425: On or before January 9, 2018, the spoil pile was not set back from the trench wall. An employee was exposed to collapse hazards while working at a depth of 6 feet 5 inches.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Bella Enterprises, INC.