Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J.E. MILLER, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of J.E. MILLER, INC. in 747 W. MANLIUS ST., EAST SYRACUSE, NY 13057 (NAICS 332710). OSHA activity number 342872439.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J.E. Miller, INC. — free Get an email when a new federal OSHA severe-injury report for J.E. Miller, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
J.E. MILLER, INC.
Site address
747 W. MANLIUS ST.
City
EAST SYRACUSE
State
NY
ZIP
13057
Mailing
747 W. MANLIUS ST., EAST SYRACUSE, NY 13057
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
13
Ownership type
A

9 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 2 instances 2 exposed
Issued
Feb 9, 2018
Abate by
Mar 16, 2018
Penalty
Initial $3,696 · Current $2,365 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by the load should the components of the overhead hoist/bridge cranes fail:  a)  1501 Building, on or about 1/16/18:  Safety latch was missing on the lifting hook for the Coffing 1/2 ton overhead hoist.  The jib crane that the 1/2 ton hoist was attached to was only rated for 750 lbs.  No inspections were conducted of the hoist and crane system.  b)  1501 Building, on or about 1/16/18:  A one ton Dayton overhead hoist was attached to a steel beam with no rated load capacity markings on it and no inspections were conducted of the hoist and crane system.  Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $2365.44
  • — Z (S) $3696

1910.101 B

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 9, 2018
Abate by
Feb 21, 2018
Penalty
Initial $2,956 · Current $1,892 Reduced
29 CFR 1910.101(b):  Section 3.4.4, Compressed Gas Association Pamphlet P-1-1965, as adopted by 29 CFR 1910.101(b): Compressed gas cylinder(s) not in use were not properly supported to prevent them from being knocked over:  a)  747 Building, Mezzanine, Heat Treat Booth, on or about 1/11/18:  An oxygen cylinder was not secured to prevent it from being knocked over.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $1891.84
  • — Z (S) $2956

1910.101 B

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 9, 2018
Abate by
Feb 21, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.101(b): Section 3.3.8, Compressed Gas Association pamphlet P-1-1965, as adopted by 29 CFR 1910.101(b):  Where caps were provided for valve protection, such caps were not kept on cylinders in storage:  a)  Mezzanine, on or about 1/11/18:  An oxygen cylinder in storage and not being used did not have the gauges and hoses removed and a valve protection cap in place.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C01

Serious Gravity 5 1 instance 10 exposed
Issued
Feb 9, 2018
Abate by
Apr 13, 2018
Penalty
Initial $3,696 · Current $2,365 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    a)  At the establishment, on or about 1/11/18:  Where employees perform servicing, setup, changeovers, and/or maintenance on various machinery and equipment including, but not limited to saws, mills, lathes, planer, etc., the employer had not established a lockout/tagout program which includes written energy control procedures, training of all authorized and affected employees, periodic inspections of the written procedures and lockout/tagout hardware to prevent the unexpected energizing, start up or release of stored energy of the equipment.    Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $2365.44
  • — Z (S) $3696

1910.157 G01

Serious Gravity 1 1 instance 13 exposed
Issued
Feb 9, 2018
Abate by
Mar 16, 2018
Penalty
Initial $2,217 · Current $1,419 Reduced
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:  a)  At the establishment, on or about 1/11/18:   Training was not provided to employees on the use of fire extinguishers and the hazards involved with incipient stage fire fighting.  *ABATEMENT NOTE:  By this date the employer must either correct the alleged violation or implement a Fire Safety Policy as outlined in 29 CFR 1910.38 and 29 CFR 1910.39 which includes the evacuation requirements of 29 CFR 1910.157(b).  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $1418.88
  • — Z (S) $2217

1910.212 A01

Serious Gravity 5 8 instances 4 exposed
Issued
Feb 9, 2018
Abate by
Mar 16, 2018
Penalty
Initial $3,696 · Current $2,365 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and moving parts:  a)  747 Building, Front Shop, on or about 1/11/18:  Rotating chucks on a Bridgeport Romi 13-5 lathe and South Bend lathe #3 were not guarded.  b)  747 Building, Front Shop, on or about 1/11/18:  Rotating chucks on a Rockwell drill press #16, and two Delta drill presses #19 and #53 were not guarded.  c) 747 Building, Front Shop, on or about 1/11/18:  Point of operation on a Cincinnati Hypro planer was not guarded.  d)  747 Building, Back Bldg., on or about 1/11/18:  Unused portion of blade on a Hyd Mech horizontal bandsaw was not guarded on the right side.  e)  1501 Building, on or about 1/16/18:  Point of operation on a DeVlieg horizontal mill was not guarded.  Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $2365.44
  • — Z (S) $3696

1910.242 B

Serious Gravity 1 2 instances 2 exposed
Issued
Feb 9, 2018
Abate by
Feb 21, 2018
Penalty
Initial $2,217 · Current $1,419 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  a)  1501 Building, on or about 1/16/18:  Compressed air gun at the Bullard turret lathe measured >100 psi.  b)  1501 Building, on or about 1/16/18:  Compressed air gun at the DeVlieg horizontal mill measured >100 psi.  Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $1418.88
  • — Z (S) $2217

1910.305 G01 IV A

Serious Gravity 5 4 instances 3 exposed
Issued
Feb 9, 2018
Abate by
Mar 16, 2018
Penalty
Initial $3,696 · Current $2,365 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a)  1501 Building, Welding Dept., on or about 1/16/18:  A 480 volt flexible cable with a metal outlet box attached, providing current to a Lincoln welder, was strung overhead, over a storage rack and was being used as permanent wiring.  b)  1501 Building, Dock Area, on or about 1/16/18:  Extension cord providing current to a Speedaire air dryer was being used as permanent wiring.  c)  1501 Building, on or about 1/16/18:  Extension cord providing current to a readout on a Bullard turret lathe was being used as permanent wiring.  d)  1501 Building, on or about 1/16/18:  Extension cord providing current to a readout, indicator and light on a DeVlieg horizontal mill was being used as permanent wiring.  Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $2365.44
  • — Z (S) $3696

1910.304 G05

Other-than-serious 1 instance 1 exposed
Issued
Feb 9, 2018
Abate by
Feb 21, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  a)  In the shop, on or about 1/11/18:  A Hossfeld hydraulic bender was not grounded in that the ground pin was missing from the plug end.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View J.E. Miller, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342872439.