FULTON, NY —
OSHA Inspection: ROWLEE CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ROWLEE CONSTRUCTION, INC. in 957 SOUTH 1ST STREET (RT 57), FULTON, NY 13069 (NAICS 236220). OSHA activity number 342877586.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROWLEE CONSTRUCTION, INC.
- Site address
- 957 SOUTH 1ST STREET (RT 57)
- City
- FULTON
- State
- NY
- ZIP
- 13069
- Mailing
- 81 PIERCE DRIVE, FULTON, NY 13069
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 12
- Ownership type
- A
Citations
9 citations on file for this inspection.
1926.153 G
- Issued
- Feb 7, 2018
- Penalty
- Initial $4,434 · Current $0 Reduced
General-duty citation text
29 CFR 1926.153(g): Liquefied petroleum gas (LP-Gas) containers inside buildings or structures were not upright upon firm foundation or otherwise firmly secured: a) West side of building, main entry, on or about 1-12-18: One employee was using the main entryway for access to and from a building, immediately adjacent to three 100 pound Liquefied Petroleum Gas (LPG) tanks that were not secured.
Recent events (2)
- — I (O) $0
- — Z (S) $4434
1926.153 J
- Issued
- Feb 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.153(j): Container(s) of liquefied petroleum gas (LP-Gas) were stored within buildings: a) West side of building, main entry, on or about 1-12-18: One employee was using the main entryway for access to and from a building, immediately adjacent to three 100 pound Liquefied Petroleum Gas (LPG) tanks that were stored indoors.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.404 B01 II
- Issued
- Feb 7, 2018
- Penalty
- Initial $2,956 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a) Basement, furnace receptacle, on or about 1-12-18: Employees were operating a 36 inch circulating fan, powered through a receptacle that was not protected by a ground fault circuit interrupter (GFCI).
Recent events (2)
- — I (O) $0
- — Z (S) $2956
1926.405 A02 II E
- Issued
- Feb 7, 2018
- Penalty
- Initial $4,434 · Current $0 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage: a) First floor, main corridor, on or about 1-12-18: one employee was working in the vicinity of multiple temporary lights that were not protected from accidental contact by bulb guards.
Recent events (2)
- — I (O) $0
- — Z (S) $4434
1926.502 I02
- Issued
- Feb 7, 2018
- Penalty
- Initial $4,434 · Current $4,434
General-duty citation text
29 CFR 1926.502(i)(2): All other covers were not capable of supporting, without failure, at least twice the weight of the employees, equipment, and materials that maybe be imposed on the cover at any one time: a) First floor, on or about 1-12-18: Employees were walking and/or working in the immediate vicinity of multiple floor openings with covers that were not sufficient enough to support imposed loads without failure, in that they used furnace filter media for covers. b) First floor, on or about 1-12-18: Employees were walking and/or working in the immediate vicinity of multiple floor openings with wood covers that were not sufficient enough to support imposed loads without failure, in that they were the same size as the cut-out and secured with one screw.
Recent events (2)
- — I (S) $4434
- — Z (S) $4434
1926.502 I03
- Issued
- Feb 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees: a) First floor, on or about 1-12-18: Employees were walking and/or working in the immediate vicinity of multiple floor openings with wood covers that were not secured sufficiently enough to support imposed loads without failure, in that they were secured with one screw or not secured at all.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 I04
- Issued
- Feb 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard: a) First floor, on or about 1-12-18: Employees were walking and/or working in the immediate vicinity of multiple floor openings with covers that were not marked.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1052 C01 I
- Issued
- Feb 7, 2018
- Penalty
- Initial $2,956 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) First floor stairway to basement, on or about 1-12-18: Employees were using a stairway without a hand rail, exposing the employees to a fall hazard of 8 feet 8 inches.
Recent events (2)
- — I (O) $0
- — Z (S) $2956
1926.405 G02 IV
- Issued
- Feb 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) Basement, temporary power panel, on or about 1-12-18: Employees were operating various hand held power tools that were plugged into two extension cords that exhibited a broken strain relief. hereby eliminating the hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Rowlee Construction, INC.