CAMPBELL, NY —
OSHA Inspection: ADECCO STAFFING ONSITE, CORNING INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ADECCO STAFFING ONSITE, CORNING INC. in 8600 MAIN STREET, CAMPBELL, NY 14821 (NAICS 561320). OSHA activity number 342878725.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADECCO STAFFING ONSITE, CORNING INC.
- Site address
- 8600 MAIN STREET
- City
- CAMPBELL
- State
- NY
- ZIP
- 14821
- Mailing
- 1 WEST MARKET STREET STE 401, CORNING, NY 14830
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561320
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.22 A03
- Issued
- Jan 24, 2018
- Penalty
- Initial $6,097 · Current $6,000 Reduced
General-duty citation text
29 CFR 1910.22(a)(3): Walking-working surfaces were not maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice: a) On or about 10/13/2017, Platforms near pond: Metal platforms were corroded.
Recent events (3)
- — J (O) $6000
- — C (S) $6097
- — Z (S) $6097
1910.22 B
- Issued
- Jan 24, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(b): The employer did not ensure that each walking-working surface can support the maximum intended load for that surface. a) On or about 10/13/2017, Platforms near pond: The employer had not ensured that the deteriorated metal platforms would support the intended load.
Recent events (3)
- — J (O) $0
- — C (S) $0
- — Z (S) $0
1910.28 B03 II
- Issued
- Jan 24, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(3)(ii): Each employee was not protected from tripping into or stepping into or through any hole that is less than 4 feet (1.2 m) above a lower level by covers or guardrail systems: a) On or about 10/13/2017, Platforms near pond: Platforms located next to the ponds and above pits less than four feet in depth had unprotected holes 50 inches long by six and twelve inches wide. b) On or about 10/13/2017, Walkway in tank building: Two holes, nine inches by three inches and nine inches by two and a half inches were not covered.
Recent events (3)
- — J (O) $0
- — C (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Jan 24, 2018
- Penalty
- Initial $8,130 · Current $6,504 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about 10/13/2017, Belt Press Building: Pinch points created by belts, rollers and drive rollers were not guarded or protected by an appropriately adjusted emergency stop able or a guard.
Recent events (3)
- — J (O) $6504
- — C (S) $8130
- — Z (S) $8130
1910.303 G02 I
- Issued
- Jan 24, 2018
- Penalty
- Initial $10,163 · Current $7,008 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) On or about 10/13/2017, New Process Building: Employees were exposed to unguarded energized parts of a transformer located inside of a panel box.
Recent events (3)
- — J (O) $7008
- — C (S) $10163
- — Z (S) $10163
1910.305 G01 IV A
- Issued
- Jan 24, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring: a) On or about 10/13/2017, Various locations throughout the facility: Extension cords were being used instead of permanent power to energize various pieces of equipment such as, but not limited to valves and pumps.
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 561320)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342878725.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.