MADILL, OK —
OSHA Inspection: OKLAHOMA STEEL AND WIRE COMPANY, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of OKLAHOMA STEEL AND WIRE COMPANY, INC. in 1042 S. 1ST STREET, MADILL, OK 73446 (NAICS 332618). OSHA activity number 342881521.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OKLAHOMA STEEL AND WIRE COMPANY, INC.
- Site address
- 1042 S. 1ST STREET
- City
- MADILL
- State
- OK
- ZIP
- 73446
- Mailing
- P.O. BOX 220, MADILL, OK 73446
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332618
- Employees
- 360
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.22 A01
- Issued
- Jul 9, 2018
- Abate by
- Jul 24, 2018
- Penalty
- Initial $12,934 · Current $7,000 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition: The employer does not ensure routine cleaning of soap/milscale resulting significant accumulation of combustible dust. This violation was observed on or about January 16, 2018 in the wire draw area, exposing employees to dust explosion, deflagration, and other fire hazards.
Recent events (2)
- — I (S) $7000
- — Z (S) $12934
1910.147 C04 I
- Issued
- Jul 9, 2018
- Abate by
- Jul 24, 2018
- Penalty
- Initial $12,934 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about January 11, 2018, in the ¼ inch wire draw area, the employer does not ensure the lockout or tagout procedures are utilized during equipment maintenance and service, exposing employees to amputations hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $12934
1910.147 C07 I
- Issued
- Jul 9, 2018
- Abate by
- Jul 24, 2018
- Penalty
- Initial $12,934 · Current $7,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: On or about January 11, 2018 and at times prior thereto, in the 1/4 inch wire draw area, the employer does not ensure that the purpose and function of the energy control program are understood by employees, exposing employees to amputations hazards.
Recent events (2)
- — I (S) $7000
- — Z (S) $12934
1910.184 D
- Issued
- Jul 9, 2018
- Abate by
- Jul 24, 2018
- Penalty
- Initial $11,086 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.184(d): Each day before being used, slings and all fastenings and attachments were not inspected for damage or defects by a competent person designated by the employer: The employer does not ensure steel alloy slings are inspected. This violation was observed or about January 16, 2018, in the ¼ inch wire draw area, exposing employees to struck-by and crushed-by hazards.
Recent events (2)
- — I (O) $5000
- — Z (S) $11086
1910.184 E01
- Issued
- Jul 9, 2018
- Abate by
- Jul 24, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach: The employer does not ensure slings have permanently affixed durable identification tags. This violation was observed on or about January 16, 2018 in the ¼ inch wire draw area, exposing employees to struck-by and crushed-by hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.212 A01
- Issued
- Jul 9, 2018
- Abate by
- Sep 24, 2018
- Penalty
- Initial $12,934 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. On or about January 16, 2018, the employer does not ensure that ingoing nip points in the 1/4 inch galvanizing and combo lines are guarded. Employees are exposed to caught-in and amputation hazards.
Recent events (2)
- — I (O) $2000
- — Z (S) $12934
1910.252 A02 VII
- Issued
- Jul 9, 2018
- Abate by
- Aug 24, 2018
- Penalty
- Initial $12,934 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.252(a)(2)(vii): Relocation of combustibles was impracticable, acutting or weldin gwas permitted when combustible were not protected with flame-proofed covers or otherwise shielded with metal, asbestos guards, or curtains. On or about May 08, 2018, in the 1/4 in wire draw area, the employer permitted welding in the area with combustible dust accumulations present, exposing employees to dust explosion, deflagration and other fire hazards.
Recent events (2)
- — I (O) $2000
- — Z (S) $12934
1910.305 G01 IV A
- Issued
- Jul 9, 2018
- Abate by
- Jul 24, 2018
- Penalty
- Initial $7,391 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: The employer does not ensure that extension cords (flex wiring) are not used as a substitute for fixed wiring. This violation was observed on or about January 16, 2018 in the ¼ inch wire draw area, exposing employees to electrical hazards.
Recent events (2)
- — I (O) $3000
- — Z (S) $7391
1910.307 C
- Issued
- Jul 9, 2018
- Abate by
- Jul 24, 2018
- Penalty
- Initial $12,934 · Current $0 Reduced
General-duty citation text
29 CFR 1910.307(c): Electrical equipment in a hazardous (classified) location was not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: On or about May 8, 2018, the employer did not ensure locations that have a presence of combustible dust use electrical equipment that is intrinsically safe, approved for the location or safe for the hazardous location. a) In the wire draw cages, a Guardair 55 gallon industrial vacuum was used for cleaning combustible dusts exposing employees to dust explosion, deflagration and other fire hazards. b) In the wire draw cages, overhead lights provided are not approved for the location, exposing employees to dust explosion, deflagration, and other fire hazards. c) In the wire draw cages, outlets and panel disconnects are not approved for the location, exposing employees to dust explosion, deflagration and other fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $12934
More inspections at Oklahoma Steel and Wire Company, INC.
View Oklahoma Steel and Wire Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332618)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342881521.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.