Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CROSS COUNTRY, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of CROSS COUNTRY, LLC in 1072 HWY 76 SOUTH P.O. BOX 629, BLANCHARD, OK 73010 (NAICS 323113). OSHA activity number 342886140.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cross Country, LLC — free Get an email when a new federal OSHA severe-injury report for Cross Country, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CROSS COUNTRY, LLC
Site address
1072 HWY 76 SOUTH P.O. BOX 629
City
BLANCHARD
State
OK
ZIP
73010
Mailing
P.O. BOX 629, BLANCHARD, OK 73010
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323113
Employees
5
Ownership type
A

9 citations on file for this inspection.

1910.37 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 9, 2018
Abate by
Jul 17, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2):  Each exit was not clearly visible and marked by a sign reading "Exit":  On or about January 18, 2018 and at times prior there to, the employer did not ensure each exit door was clearly marked "Exit".  This exposed the employees to caught in fire hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 C

Serious Gravity 5 2 instances 3 exposed
Issued
Jul 9, 2018
Abate by
Jul 31, 2018
Penalty
Initial $2,772 · Current $1,400 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use.    On or about January 18, 2018 and at times prior there to, the employer did not provide access to suitable facilities for quick drenching or flushing of the eyes and body in areas where employees were exposed to corrosive materials.    Instance 1 In the screen printing ink application and drying area.    Instance 2 In the screen wash room.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2772

1910.157 C01

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 9, 2018
Abate by
Jul 31, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries.  On or about January 18, 2018 and at times prior there to, the employer did not ensure the portable fire extinguishers were mounted and identified for employee use.  This exposed employees to fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 C04

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 9, 2018
Abate by
Jul 17, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(c)(4): Snap switches mounted in boxes did not have faceplates installed so as to completely cover the opening and seat against the finished surface.  On or about January 18, 2018 and at times prior thereto, the employer did not ensure the faceplate on a light switch was installed.  This exposed employees to a electrical shock hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 D02

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 9, 2018
Abate by
Jul 17, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(d)(2): Panelboards were not mounted in cabinets that were dead front.  On or about January 18, 2018 and at times prior thereto, the employer did not ensure the cabinet that the panelboard was mounted in had a dead front.  This exposed employees to a electrical shock/electrocution hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 E01

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 9, 2018
Abate by
Jul 17, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(e)(1): Cabinets, boxes, and panelboard enclosures in damp or wet locations were not installed to prevent moisture or water from entering and accumulating within the enclosures.  On or about January 18, 2018 and at times prior thereto, the employer did not ensure that a cabinet and panelboard enclosure, located inside of the wet environment of the power wash room, were installed to prevent moisture or water from entering and accumulating within the enclosure.  This exposed the employees to a electrical shock/electrocution hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 9, 2018
Abate by
Sep 30, 2018
Penalty
Initial $2,217 · Current $1,100 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met.    On or about January 18, 2018 and at times prior thereto, the employer did not develop and implement a written hazard communication program.  Employees use a variety of chemicals including corrosives and were exposed to chemical hazards.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $2217

1910.1200 G08

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 9, 2018
Abate by
Sep 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8):   The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work  shift to employees when they were in their work area(s).    On or about January 18, 2018 and at times prior there to, the employer did not maintain safety data sheet information on chemicals used.  This exposed employees to chemical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 9, 2018
Abate by
Sep 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:      On or about January 18, 2018 and at times prior there to, the employer did not provide training on hazardous chemicals used in the work area and how employees need to protect themselves from exposure or accidental release inside work areas.  This exposed employees to chemical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342886140.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.