ELK GROVE VILLAGE, IL —
OSHA Inspection: CRESCENT ELECTRIC SUPPLY COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CRESCENT ELECTRIC SUPPLY COMPANY in 1700 ESTES AVE, ELK GROVE VILLAGE, IL 60007 (NAICS 423610). OSHA activity number 342888286.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CRESCENT ELECTRIC SUPPLY COMPANY
- Site address
- 1700 ESTES AVE
- City
- ELK GROVE VILLAGE
- State
- IL
- ZIP
- 60007
- Mailing
- 1700 ESTES AVE, ELK GROVE VILLAGE, IL 60007
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423610
- Employees
- 26
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.176 B
- Issued
- Jul 12, 2018
- Abate by
- Aug 7, 2018
- Penalty
- Initial $12,934 · Current $0 Reduced
General-duty citation text
29 CFR 1910.176(b): Storage was not secured. Storage of material must not create a hazard. Bags, containers, bundles, etc., stored in tiers shall be stacked, blocked, interlocked and limited in height so that they are stable and secure against sliding or collapse. a) Wire Cage Area - On or about January 19, 2018, an employee operating the Reel-O-Matic machine sustained multiple injuries when a cable at then end of a 600 pound reel got tangled on the support pipe and came off the rack striking the employee.
Recent events (2)
- — I (S) $0
- — Z (S) $12934
More inspections at Crescent Electric Supply Company
View Crescent Electric Supply Company's full OSHA safety record →
More inspections in this industry (NAICS 423610)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342888286.