OSHA Inspection: AIM NATIONAL LEASE

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of AIM NATIONAL LEASE in 2975 OLD OAKWOOD DRIVE, GAINESVILLE, GA 30504 (NAICS 811111). OSHA activity number 342895612.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AIM National Lease — free Get an email when a new federal OSHA severe-injury report for AIM National Lease is published. One employer, no account, unsubscribe in one click.
Establishment
AIM NATIONAL LEASE
Site address
2975 OLD OAKWOOD DRIVE
City
GAINESVILLE
State
GA
ZIP
30504
Mailing
1500 TRUMBULL AVENUE, GIRARD, OH 44420
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
20
Ownership type
A

5 citations on file for this inspection.

1910.1200 F06 II

Other-than-serious 2 instances 20 exposed
Issued
Apr 30, 2018
Abate by
May 10, 2018
Penalty
Initial $5,543 · Current $3,500 Reduced
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical:    AIM Leasing Company, Gainesville, GA - On or about January 22, 2018, and at times prior, the employer did not ensure that all containers that had unknown chemicals, was properly label.  Examples include, but are not limited to:     a)A black antifreeze coolant container used by all employees in the shop area was not labeled.    b) In the chemical cabinet shop, there were several cans/bottles with missing labels.    Also, there was no hazard statement, pictogram and/or precautionary statements.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $3500
  • — Z (S) $5543

1910.37 A04

Deleted Other-than-serious 1 instance 20 exposed
Issued
Apr 30, 2018
Abate by
May 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:  AIM Leasing Company, Gainesville, GA - On or about January 22, 2018, and at times prior to, employees were exposed to fire and smoke inhalation hazards when emergency safeguard such as an emergency lighting, at the end of the shop next to the bay door, did not illuminate when tested.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 C01

Other-than-serious 1 instance 20 exposed
Issued
Apr 30, 2018
Abate by
May 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  AIM Leasing Company, Gainesville, GA - On or about January 22, 2018, and at times prior to, employees were exposed to fire and smoke inhalation hazards when fire extinguishers were not mounted, located and identified for ready and safe access by employees in the following areas:  a) Break room- A portable fire extinguisher was located on the floor (used as a door stop) and was not mounted or its location identified.    b)  Mechanic Shop by exit door next to the rest area - The employer did not ensure that the fire extinguisher was properly marked exposing employees to possible smoke inhalation and burns.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.253 B04 III

Deleted Other-than-serious 1 instance 20 exposed
Issued
Apr 30, 2018
Abate by
May 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet:  AIM Leasing Company, Gainesville, GA - On our about January 22, 2018, and at times prior to, employees were exposed to fire hazards when compressed gas cylinders used for oxy-fuel gas welding were not separated after use.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G02 I

Other-than-serious 1 instance 5 exposed
Issued
Apr 30, 2018
Abate by
May 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  AIM Leasing Company, Gainesville, GA - Upstairs storage area- On or about January 22, 2018, and at times prior to, employees were exposed to electric shock hazards when the electrical box cover was missing and live electrical parts were exposed.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View AIM National Lease's full OSHA safety record →