OSHA Inspection: INDIAN RIVER TRANSPORT CO

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of INDIAN RIVER TRANSPORT CO in 2580 EXECUTIVE RD, WINTER HAVEN, FL 33884 (NAICS 484230). OSHA activity number 342896321.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Indian River Transport CO — free Get an email when a new federal OSHA severe-injury report for Indian River Transport CO is published. One employer, no account, unsubscribe in one click.
Site address
2580 EXECUTIVE RD
City
WINTER HAVEN
State
FL
ZIP
33884
Mailing
2580 EXECUTIVE RD, WINTER HAVEN, FL 33884
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484230
Employees
40
Ownership type
A

9 citations on file for this inspection.

1910.38 B

Serious Gravity 1 1 instance 40 exposed
Issued
Jul 2, 2018
Abate by
Aug 17, 2018
Penalty
Initial $5,543 · Current $5,543
29 CFR 1910.38(b): An emergency action plan was not in writing, kept in the workplace, and available to employees for review:  a) At the facility, the employer did not develop an Emergency Action Plan, when employees evacuate during a fire emergency, on or about January 17, 2018.
Recent events (1)
  • — Z (S) $5543

1910.39 B

Serious Gravity 1 1 instance 40 exposed
Issued
Jul 2, 2018
Abate by
Aug 6, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.39(b): A fire prevention was not in writing, kept in the workplace, and made available to employees for review:  a) At the facility, the employer did not develop a Fire Prevention Plan when employees evacuate during a fire emergency, on or about January 17, 2018.
Recent events (1)
  • — Z (S) $0

1910.1200 E01

Serious Gravity 1 1 instance 20 exposed
Issued
Jul 2, 2018
Abate by
Aug 6, 2018
Penalty
Initial $5,543 · Current $5,543
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):   (a)  For employees working with chemicals such as but not limited to; Mandate Plus Acid Sanitizer, Quorum Yellow II Chlorinated Alkaline Cleaner, AC 55-8 Red Acid Cleaner, CS 300 Acid Cleaner, Shell Rotella md T3 Fleet SAE 15w-40, Clear Vision Concentrated Washer Fluid, Warren AW-68 Anti Ware Hydraulic Oil, Phillips 66 Multiplex Red Grease #2, Shell Spirax S6 AXRME SAE 75w-90,  Shell Rotella ELC Nitrate Fee diluted 50/50, Shell Gadus md S3 V220C and Non-Chlorinated Brake Cleaner, on or about January 17, 2018.
Recent events (1)
  • — Z (S) $5543

1910.1200 E01 I

Serious Gravity 1 1 instance 40 exposed
Issued
Jul 2, 2018
Abate by
Aug 6, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet:  (a)  For employees working in the Service Department with chemicals such as but not limited to; Shell Rotella md T3 Fleet SAE 15w-40, Clear Vision Concentrated Washer Fluid, Warren AW-68 Anti Ware Hydraulic Oil, Phillips 66 Multiplex Red Grease #2, Shell Spirax S6 AXRME SAE 75w-90,  Shell Rotella ELC Nitrate Fee diluted 50/50, Shell Gadus md S3 V220C and Non-Chlorinated Brake Cleaner, on or about January 17, 2018.
Recent events (1)
  • — Z (S) $0

1910.1200 F06 I

Serious Gravity 1 3 instances 3 exposed
Issued
Jul 2, 2018
Abate by
Aug 17, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6)(i): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v):  a) In the Service Department, chemicals used by employees such as but not limited to; brake and window cleaners  that were being transferred from 55 gallon drums to smaller quantity spray bottles were not labeled, on or about January 17, 2018.
Recent events (1)
  • — Z (S) $0

1910.37 A03

Other-than-serious 2 instances 10 exposed
Issued
Jul 2, 2018
Abate by
Jul 13, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  a) For employees working in the Service Department, designated exits were partially blocked by supplies, on or about January 17, 2018.  b) For employees working in Trailer and Tire Departments, designated exit was completely blocked by equipment and supplies, on or about January 17, 2018.
Recent events (1)
  • — Z (O) $0

1910.157 C04

Other-than-serious 1 instance 5 exposed
Issued
Jul 2, 2018
Abate by
Jul 16, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition:  (a) In the Trailer Department, a wall hung portable fire extinguisher was in need to be serviced, on or about January 17, 2018.
Recent events (1)
  • — Z (O) $0

1910.157 G01

Other-than-serious 1 instance 1 exposed
Issued
Jul 2, 2018
Abate by
Aug 6, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:  (a)  At the facility, employees working in the Service and Tank Departments were allowed to use fire extinguishers without being trained, on or about January 17, 2018.
Recent events (1)
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 3 instances 5 exposed
Issued
Jul 2, 2018
Abate by
Jul 16, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  (a) For employees working in the Service Department, an electrical panel being used for machinery and lighting was partially blocked from pallets of supplies being stored in front, on or about January 17, 2018.  (b)  For employees working in the Trailer Department were equipment and supplies had been placed in front of electrical panels being used for machinery, fans and lighting, on or about January 17, 2018.