ROME, NY —
OSHA Inspection: J. PRIORE CONSTRUCTION CO., INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of J. PRIORE CONSTRUCTION CO., INC. in 801 LAUREL STREET, ROME, NY 13440 (NAICS 236220). OSHA activity number 342896610.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J. PRIORE CONSTRUCTION CO., INC.
- Site address
- 801 LAUREL STREET
- City
- ROME
- State
- NY
- ZIP
- 13440
- Mailing
- 316 ONTARIO STREET, UTICA, NY 13501
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 10
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.403 I02 I
- Issued
- Feb 28, 2018
- Abate by
- Mar 7, 2018
- Penalty
- Initial $3,880 · Current $0 Reduced
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph: a) At the jobsite, on or about 1/23/18: Employees were exposed to live electrical parts on the first floor where there was an open switchbox with live wires. b) At the jobsite, on or about 1/23/18: Employees were exposed to live electrical parts on the first floor along the ceiling where an open junction box had live electrical wires. c) At the jobsite, on or about 1/23/18: Employees were exposed to live electrical parts in the electrical room where a service panel was missing a breaker opening cover.
Recent events (3)
- — J (S) $0
- — C (S) $3880
- — Z (S) $3880
1926.451 F07
- Issued
- Feb 28, 2018
- Abate by
- Apr 16, 2018
- Penalty
- Initial $3,880 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: a) At the jobsite, in the stairwell, on or about 1/23/18: A worker was building a supported scaffold where fall protection components were installed, where some components were damaged, and some components were incorrectly deployed.
Recent events (3)
- — J (S) $0
- — C (S) $3880
- — Z (S) $3880
1926.502 D06 V
- Issued
- Feb 28, 2018
- Abate by
- Mar 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(6)(v): A snaphook not of the locking type was engaged to any objectwhich is incompatibly shaped or dimensioned in relation to the snaphook such that unintentional disengagement could occur by the connected object being able to depress the snaphook keeper and release itself. a) At the jobsite, in the stairwell, on or about 1/23/18: Lanyards were provided for fall protection where they were attached to the steel joists.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.502 D19
- Issued
- Feb 28, 2018
- Abate by
- Mar 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(19): Personal fall arrest systems and components subjected to impact loading were not immediately removed from service and/or were reused before they were inspected by a competent person and determined to be suitable for reuse: a) At the jobsite, in the stairwell, on or about 1/23/18: A lanyard was provided for fall protection where that lanyard was a deceleration type that had been put under load and was deployed.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.403 B02
- Issued
- Feb 28, 2018
- Abate by
- Mar 19, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) At the jobsite, on or about 1/23/18: Workers were using power strips installed for use that were designed for commercial/industrial use but not construction use.
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at J. Priore Construction CO., INC.
View J. Priore Construction CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342896610.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.