Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GRAND JUNCTION SSC FAA

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GRAND JUNCTION SSC FAA in GJT - ARSR DOUGLASS PASS, GRAND JUNCTION, CO 81506 (NAICS 921140). OSHA activity number 342898269.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Grand Junction SSC FAA — free Get an email when a new federal OSHA severe-injury report for Grand Junction SSC FAA is published. One employer, no account, unsubscribe in one click.
Site address
GJT - ARSR DOUGLASS PASS
City
GRAND JUNCTION
State
CO
ZIP
81506
Mailing
2788 PRINTERS CT, GRAND JUNCTION, CO 81506
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
921140
Employees
10000
Ownership type
D

2 citations on file for this inspection.

1910.22 A03

Serious Gravity 1 1 instance 2 exposed
Issued
May 31, 2018
Abate by
Jun 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(3): Walking-working surfaces were not maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice:  (a)  Grand Junction SSC FAA, at Douglas Pass, Grand Junction, CO 81506:  On and before January 24, 2018, the Agency did not ensure that walking-working surfaces were maintained free of hazards such as protruding objects and other trip hazards.  The Agency allowed storage of various material on the walkway between the beacon arrays, creating trip hazards, and minimizing the area employees could safely walk in.  This condition exposed employees to trippingand fall hazards.
Recent events (1)
  • — Z (S) $0

1910.147 C05 II C 1

Serious Gravity 1 1 instance 2 exposed
Issued
May 31, 2018
Abate by
Jun 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(ii)(C)(1): Lockout devices were not substantial enough to prevent removal without the use of excessive force or unusual techniques, such as with the use of bolt cutters or other metal cutting tools:  (a) Grand Junction SSC FAA, at Douglas Pass, Grand Junction, CO 81506: On and before January 24, 2018, the Agency did not ensure that an energy isolating device was substantial enough to prevent removal without the use of excessive force or unusual techniques, such as with the use of bolt cutters or other metal cutting tools.  The lockout device used to secure the sail on the long range radar at the Radome near Douglas pass was not substantial enough to prevent the dome from rotating when employees were attempting to climb the radar panel during maintenance.  This condition exposed employees to fall hazards.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342898269.