Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COLEMAN CONRETE, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of COLEMAN CONRETE, INC. in 9 NH ROUTE 113, CONWAY, NH 03818 (NAICS 327320). OSHA activity number 342901667.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Coleman Conrete, INC. — free Get an email when a new federal OSHA severe-injury report for Coleman Conrete, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9 NH ROUTE 113
City
CONWAY
State
NH
ZIP
03818
Mailing
9 NH ROUTE 113, CONWAY, NH 03818
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327320
Employees
11
Ownership type
A

4 citations on file for this inspection.

1910.95 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 2, 2018
Abate by
Jun 1, 2018
Penalty
Initial $6,468 · Current $3,234 Reduced

Hazardous substances 811081118130

29 CFR 1910.95(b)(1): When employees were subjected to sound exceeding those listed in Table G-16, feasible administrative or engineering controls were not utilized:    a.  Garage - On or about March 8, 2018, employees using an air hammer to chip out mixer drum buildup were exposed to noise levels of up to 1679.2% of the permissible daily noise dose or an eight hour time weighted average equivalent of 110.3 dBA.  The employees utilized hearing protective devices (HPDs) with an equivalent NRR of 18 dBA.  The employees' attenuated noise exposure was 92.3 dBA which exceeded the eight hour time weighted average limit of 90 dBA.  The employer failed to utilize feasible administrative or engineering controls to reduce exposure below 90 dBA.
Recent events (2)
  • — I (S) $3234
  • — Z (S) $6468

1910.95 D01

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 2, 2018
Abate by
May 7, 2018
Penalty
Initial $6,468 · Current $3,234 Reduced

Hazardous substances 811081118130

29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program:    a.  Garage - On or about March 6, 2018, employees using an air hammer to chip out mixer drum buildup were exposed to noise levels of up to 840.3% of the 85 dBA action level or an equivalent of 105.3 dBA during the 72 minute sampling period.  The exposure calculation included a zero increment for the 408 minutes not sampled.  The employer failed to develop a noise monitoring program for employees using or working near pneumatic tools.
Recent events (2)
  • — I (S) $3234
  • — Z (S) $6468

1910.95 G01

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 2, 2018
Abate by
May 7, 2018
Penalty
Initial $6,468 · Current $3,234 Reduced

Hazardous substances 811081118130

29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels:    a.  Garage - On or about March 6, 2018, employees using an air hammer to chip out mixer drum buildup were exposed to noise levels of up to 840.3% of the 85 dBA action level or an equivalent 8 hour time weighted average of 105.3 dBA during the 72 minute sampling period.  The exposure calculation included a zero increment for the 408 minutes not sampled.  The employer failed to establish an audiometric testing program for employees whose exposures exceed 85 dBA.
Recent events (2)
  • — I (S) $3234
  • — Z (S) $6468

1910.95 L01

Other-than-serious 1 instance 4 exposed
Issued
Apr 2, 2018
Abate by
May 7, 2018
Penalty
Initial $0 · Current $0

Hazardous substances 811081118130

29 CFR 1910.95(l)(1): The employer did not make available to affected employees or their representatives copies of 29 CFR 1910.95 and did not post a copy in the workplace:  a.  Garage - On or about March 6, 2018, employees using an air hammer to chip out mixer drum buildup were exposed to noise levels of up to 840.3% of the 85 dBA action level or an equivalent of 105.3 dBA during the 72 minute sampling period.  The exposure calculation included a zero increment for the 408 minutes not sampled.  The employer failed to make available and post a copy of the hearing conservation standard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342901667.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.