GLENVIEW, IL —
OSHA Inspection: GORAN VESELINOVIC DBA VESELI DESIGN & BUILD, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GORAN VESELINOVIC DBA VESELI DESIGN & BUILD, INC. in 742 ELMGATE DR., GLENVIEW, IL 60025 (NAICS 238130). OSHA activity number 342905460.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GORAN VESELINOVIC DBA VESELI DESIGN & BUILD, INC.
- Site address
- 742 ELMGATE DR.
- City
- GLENVIEW
- State
- IL
- ZIP
- 60025
- Mailing
- 2436 ROBINCREST LANE, GLENVIEW, IL 60025
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.102 A01
- Issued
- Apr 20, 2018
- Penalty
- Initial $1,663 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment was not used when machines or operations presented potential eye or face injury: a) On January 26, 2018, an employee was using a circular hand-held saw to cut lumber without protective eye equipment.
Recent events (2)
- — I (S) $1000
- — Z (S) $1663
1926.416 A01
- Issued
- Apr 20, 2018
- Penalty
- Initial $2,772 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.416(a)(1): The employer permitted employees to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work and was not protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means: a) On or about January 26, 2018, employees performing carpentry work were permitted to work in proximity to an energized 240 volt overhead power line, thereby exposing employees to electric shock hazards.
Recent events (2)
- — I (S) $1000
- — Z (S) $2772
1926.501 B13
- Issued
- Apr 20, 2018
- Abate by
- Apr 26, 2018
- Penalty
- Initial $2,217 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On January 26, 2018, an employee was performing residential carpentry work without fall protection, exposing the employee to a fall hazard of approximately twelve (12) feet.
Recent events (2)
- — I (S) $1000
- — Z (S) $2217
1926.404 B01 I
- Issued
- Apr 20, 2018
- Abate by
- Apr 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) On January 26, 2018, employees were provided with electrical tools and equipment connected by cord and plug without the use of an assured equipment grounding program or Ground Fault Circuit Interrupters (GFCI's).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.404 F06
- Issued
- Apr 20, 2018
- Abate by
- Apr 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) On January 26, 2018, the employer provided for employee use at the job site an extension cord that did not have a grounding pin.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.416 E01
- Issued
- Apr 20, 2018
- Abate by
- Apr 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) On January 26, 2018, the insulation on an extension cord being used by employees to provide electricity to hand held power tools was worn at the strain relief as evidenced by the exposed insulated conductors.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238130)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342905460.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.