OSHA Inspection: DOMINION ENERGY TRANSMISSION, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DOMINION ENERGY TRANSMISSION, INC. in GALMISH LOAD FACILITY PINY FORK ROAD, PINE GROVE, WV 26419 (NAICS 424710). OSHA activity number 342906153.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dominion Energy Transmission, INC. — free Get an email when a new federal OSHA severe-injury report for Dominion Energy Transmission, INC. is published. One employer, no account, unsubscribe in one click.
Site address
GALMISH LOAD FACILITY PINY FORK ROAD
City
PINE GROVE
State
WV
ZIP
26419
Mailing
14510 SHORTLINE HIGHWAY, PINE GROVE, WV 26419
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424710
Employees
58
Ownership type
A

5 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 10 1 instance 9 exposed
Issued
Jun 14, 2018
Abate by
Jun 26, 2018
Penalty
Initial $12,934 · Current $12,934
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2m) or more above a lower level was protected from falling by guardrail systems, safety net system, or personal fall arrest system:  (a) LPG Loading Rack.  On or about January 18, 2018, and times prior, the Safe Harbors TLS Gangway, used to gain access to and from railcars, had unprotected sides of 31 inches in width, exposing employees to falls of 12 feet 6 inches to ground.
Recent events (2)
  • — I (S) $12934
  • — Z (S) $12934

1910.22 D02

Serious Gravity 10 1 instance 9 exposed
Issued
Jun 14, 2018
Abate by
Jun 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(2): Hazardous conditions on walking working surfaces were not corrected or repaired before an employee used the walking-working surface:    (a) LPG Loading Rack.  On or about January 18, 2018, employees performed loading operations from the LPG loading stations, which were not corrected prior to continued use, exposing employees to falls.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.29 B02 I

Other-than-serious 1 instance 8 exposed
Issued
Jun 14, 2018
Abate by
Jun 26, 2018
Penalty
Initial $9,239 · Current $9,239
29 CFR 1910.29(b)(2)(i): Mid-rails were not installed at a height midway between the top edge of the guardrail system and the walking-working surface:     (a) LPG Loading Rack.  On or about January 25, 2018, and times prior, the safety cage attached to the TLS Gangway provided a top rail but did not provide a mid-rail for the up to 30in. by 31in. wide opening on both sides, exposing employees to falls up to 12ft. 6in. to the ground below.
Recent events (2)
  • — I (O) $9239
  • — Z (S) $9239

1910.132 A

Deleted Serious Gravity 5 1 instance 9 exposed
Issued
Jun 14, 2018
Abate by
Jun 26, 2018
Penalty
Initial $9,239 · Current $0 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:     (a) LPG railcar loading. On or about January 25, 2018, and times prior, personal protective equipment, such as personal fall arrest system was not provided to employees who accessed the top of the railcars with a railing that was up to 30in. above the platform, exposing employees to falls of up to approximately 14ft. to the ground.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9239

1910.22 A03

Deleted Serious Gravity 5 1 instance 9 exposed
Issued
Jun 14, 2018
Abate by
Jun 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(3): Walking-working surfaces were not maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice:  (a) LPG loading rack:  On or about January 18, 2018, and times prior, employees were exposed to falls of 14ft. to the ground while performing loading operations on top of railcars that had not been cleared of snow and/or ice.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0