MINNEOLA, KS —
OSHA Inspection: MINNEOLA COOP, INC.
Unprogrammed Related inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Related health inspection of MINNEOLA COOP, INC. in 500 W. FRONT STREET, MINNEOLA, KS 67865 (NAICS 424510). OSHA activity number 342909173.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MINNEOLA COOP, INC.
- Site address
- 500 W. FRONT STREET
- City
- MINNEOLA
- State
- KS
- ZIP
- 67865
- Mailing
- 415 W. FRONT STREET, MINNEOLA, KS 67865
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424510
- Employees
- 13
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.22 A01
- Issued
- May 21, 2018
- Abate by
- Jun 15, 2018
- Penalty
- Initial $3,696 · Current $2,218 Reduced
G109
General-duty citation text
29 CFR 1910.22(a)(1): The employer failed to provide a clean and sanitary condition for all places of employment, passageways, storerooms, service rooms, and walking-working surfaces. Employees performing maintenance tasks were exposed to fire and explosion hazards in that the employer did not implement their housekeeping program and dust was allowed to accumulate in the following locations: A) The leg above conveyor in the tunnel near Bin #43. Dust measured 1 and 5/8 inches deep. B) The leg above conveyor in the tunnel near Bins #35 and #36. Dust measured 3/8 of an inch deep. C) The leg above conveyor in the tunnel near Bin #27. Dust measured 7/16 of an inch deep. D) The leg above conveyor in the tunnel near Bins #31 and #32. Dust measured 1 and 7/8 inches deep. E) The floor beneath the conveyor in the tunnel near Bin #16. Dust measured 2 and 1/2 inches deep.
Recent events (2)
- — I (S) $2217.6
- — Z (S) $3696
1910.134 C01
- Issued
- May 21, 2018
- Abate by
- Jun 15, 2018
- Penalty
- Initial $2,217 · Current $1,330 Reduced
G109
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: Employer did not provide a written respiratory program to control and address the use of a MSA full face respirator with a Phosphine/Ammonia/Chlorine/P100 cartridge. Employees were exposed to inhalation hazards from phosphine gas while using the controlled restricted pesticide Killz-All 60 as a fumigant.
Recent events (2)
- — I (S) $1330.2
- — Z (S) $2217
1910.134 H02 I
- Issued
- May 21, 2018
- Abate by
- Jun 15, 2018
- Penalty
- Initial $2,956 · Current $0 Reduced
G109
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: Employer did not provide proper storage for a MSA full face respirator with a Phosphine/Ammonia/Chlorine/P100 cartridge. The respirator was stored in the same cabinet on the same shelf as the Killz-All 60 without benefit of an enclosed container to protect it from excessive moisture and leaching from the proximal pesticide. Employees were exposed to inhalation hazards from phosphine gas while using the mask while applying the controlled restricted pesticide Killz-All 60 as a fumigant.
Recent events (2)
- — I (S) $0
- — Z (S) $2956
1910.303 B01
- Issued
- May 21, 2018
- Abate by
- Jun 15, 2018
- Penalty
- Initial $3,696 · Current $2,218 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: An overhead electrical fixture mounted on the ceiling of the grain elevators tunnel near Bin #50 was not enclosed. The missing globe provided an electrical ignition source exposing workers to explosion hazards.
Recent events (2)
- — I (S) $2217.6
- — Z (S) $3696
1910.307 C01
- Issued
- May 21, 2018
- Abate by
- Jun 15, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.307(c)(1): Intrinsically safe. Equipment and associated wiring approved as intrinsically safe is permitted in any hazardous (classified) location for which it is approved; An overhead electrical fixture mounted on the ceiling of the elevators tunnel near Bin #50 was not enclosed. The missing globe provided an electrical ignition source exposing workers to explosion hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 424510)
More inspections in KS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342909173.