Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: C.M.P. PLUMBING AND HEATING, LLC

Unprogrammed Related inspection · Health discipline

On , OSHA opened an unprogrammed Related health inspection of C.M.P. PLUMBING AND HEATING, LLC in 45 W. THIRD STREET, SOUTH BOSTON, MA 02127 (NAICS 238220). OSHA activity number 342910429.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch C.M.P. Plumbing and Heating, LLC — free Get an email when a new federal OSHA severe-injury report for C.M.P. Plumbing and Heating, LLC is published. One employer, no account, unsubscribe in one click.
Site address
45 W. THIRD STREET
City
SOUTH BOSTON
State
MA
ZIP
02127
Mailing
1 CORPORATE PARK DRIVE UNIT 9, DERRY, NH 03038
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
15
Ownership type
A

4 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 16 exposed
Issued
Jul 2, 2018
Abate by
Jul 11, 2018
Penalty
Initial $726 · Current $726
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  The employer failed to provide abatement certification for hazards cited.
Recent events (1)
  • — Z (O) $726

1910.1200 H01

Serious Gravity 5 1 instance 16 exposed
Issued
May 2, 2018
Abate by
Jun 21, 2018
Penalty
Initial $5,174 · Current $5,174
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  Jobsite:  Employees have not received effective chemical hazard communication training for chemical products such as Great Stuff insulating foam sealant, and PVC pipe primer and cement.
Recent events (1)
  • — Z (S) $5174

1910.1200 E01 I

Serious Gravity 5 1 instance 15 exposed
Issued
May 2, 2018
Abate by
May 23, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present using an identity that was referenced on the appropriate material safety data sheet:   (Construction Reference: 1926.59)(a )  Location:  Job site  The company's written chemical hazard communication program lacked an inventory of hazardous chemicals.
Recent events (1)
  • — Z (S) $0

1910.1200 F09

Other-than-serious 1 instance 16 exposed
Issued
May 2, 2018
Abate by
May 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(9): The employer did not ensure that labels or other forms of warning were legible, in English, and prominently displayed on the container, or readily available in the work area throughout each work shift:  Jobsite:  company chemical storage area on first floor  The label had been removed or fallen off of a can believed to be spray paint.
Recent events (1)
  • — Z (O) $0

View C.M.P. Plumbing and Heating, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342910429.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.