ADDISON, IL —
OSHA Inspection: HERMAN SEEKAMP, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HERMAN SEEKAMP, INC. in 1120 W. FULLERTON AVE., ADDISON, IL 60101 (NAICS 311812). OSHA activity number 342910825.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HERMAN SEEKAMP, INC.
- Site address
- 1120 W. FULLERTON AVE.
- City
- ADDISON
- State
- IL
- ZIP
- 60101
- Mailing
- 1120 W. FULLERTON AVE., ADDISON, IL 60101
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311812
- Employees
- 142
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.212 A01
- Issued
- Jul 20, 2018
- Abate by
- Aug 27, 2018
- Penalty
- Initial $11,641 · Current $7,550 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Line #3, DCA Dough Sheeter Machine. a. On or about January 26, 2018 through January 30, 2018, the ingoing nip points created between the sheeter rollers at the individual sheeter stations were not adequately guarded to protect the operators' hands/fingers from getting caught in the ingoing nips (points of operation) between the rollers. Line #3, DCA Sheeter Stamper. b. On or about January 30, 2018, the guard opening at the entrance to the stamper was not adequate to prevent entry with hands/fingers into the point of operation. Abatement documentation is required for Instance a. in accordance with 29 CFR 1903.19(d). There is no abatement documentation required for Instance b. which was Corrected During Inspection.
Recent events (2)
- — I (S) $7550
- — Z (S) $11641
More inspections at Herman Seekamp, INC.
View Herman Seekamp, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311812)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342910825.