SEATTLE, WA —
OSHA Inspection: U.S COAST GUARD BASE SEATTLE; FACILITIES ENGINEERING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of U.S COAST GUARD BASE SEATTLE; FACILITIES ENGINEERING in BUILDINGS 3 AND 14, SEATTLE, WA 98134 (NAICS 561790). OSHA activity number 342911039.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S COAST GUARD BASE SEATTLE; FACILITIES ENGINEERING
- Site address
- BUILDINGS 3 AND 14
- City
- SEATTLE
- State
- WA
- ZIP
- 98134
- Mailing
- 1519 ALASKAN WAY SOUTH, SEATTLE, WA 98134
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561790
- Employees
- 15
- Ownership type
- D
Citations
10 citations on file for this inspection.
1910.28 B01 I
- Issued
- Feb 13, 2018
- Abate by
- Apr 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2m) or more above a lower level was protected from falling by guardrail systems, safety net system, or personal fall arrest systems, such as personal fall arrest, travel restraint, or positioning systems: a) Warehouse Penthouse, where employees were exposed to an approximate 20 foot fall while removing and replacing the removable section of the guard rail system located in the loading area.
Recent events (1)
- — Z (S) $0
1910.213 C01
- Issued
- Feb 13, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a) Carpenter Shop, where employees operated the SawStop, model #ICS-53230, table saw without the hood guard.
Recent events (1)
- — Z (S) $0
1910.213 C02
- Issued
- Feb 13, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: a) Carpenter Shop, where employees operated the Saw Stop, model #ICS-53230, table saw without the spreader.
Recent events (1)
- — Z (S) $0
1910.213 C03
- Issued
- Feb 13, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: a) Carpenter Shop, where employees operated the Saw Stop, model #ICS-53230, table saw without nonkickback fingers or dogs.
Recent events (1)
- — Z (S) $0
1960.59 A
- Issued
- Feb 13, 2018
- Abate by
- Apr 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1960.59(a): The Agency did not provide specialized job safety and health training appropriate to the work performed by the employee: a) Carpenter Shop, where employees were not provided with training pertaining to the proper use of power tools, such as but not limited to, the SawStop table saw, model #ICS-53230.
Recent events (1)
- — Z (S) $0
1910.213 H04
- Issued
- Feb 13, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(h)(4): Radial saw(s) installation was not in such a manner that the front end of the unit was slightly higher than the rear, so as to cause the cutting head to return gently to the starting position when released by the operator: a) Carpenter Shop, where the De Walt 790 radial arm saw did not return to the starting position.
Recent events (1)
- — Z (S) $0
1910.215 B09
- Issued
- Feb 13, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) Weld Shop, where tongue guards not adjusted properly included: 1. De Walt bench grinder, where the tongue guard measured 1/2 inch from the abrasive wheel located on the right side. 2. Electric Clark pedestal grinder, where the tongue guard measured 3/4 inch from the abrasive wheel located on the right side and ½ inch from the abrasive wheel located on the left side.
Recent events (1)
- — Z (S) $0
1910.303 B02
- Issued
- Feb 13, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling: a) Facility Maintenance Shops, where equipment not used as listed or labeled included: 1. Electrician Shop, where the relocatable power tap located on top of the file cabinet was used to supply power to appliances including the Sensor microwave oven. 2. Electrician shop, where the relocatable power tap located on the floor was used to supply power to appliances including the GE refrigerator. 3. Weld Shop, where the Fellows relocatable power tap located adjacent to the pedestal grinder was used to supply power to the Milwaukee chargers.
Recent events (1)
- — Z (S) $0
1910.22 D01
- Issued
- Feb 13, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate: a) Carpenter Shop, where scrap lumber was stored on the roof of the locksmith office a load rating was not posted.
Recent events (1)
- — Z (O) $0
1910.28 B11 II
- Issued
- Feb 13, 2018
- Abate by
- Apr 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(11)(ii): Each flight of stairs having at least 3 treads and at least 4 risers was not equipped with stair rail systems and handrails as required by Table D-2- Stairway Handrail Requirements: a) Penthouse H Area, where the stair rail system on the stairway to the catwalk lacked a mid-rail on the right side.
Recent events (1)
- — Z (O) $0
More inspections at U.S Coast Guard Base Seattle; Facilities Engineering
View U.S Coast Guard Base Seattle; Facilities Engineering's full OSHA safety record →
More inspections in this industry (NAICS 561790)
More inspections in WA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342911039.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.