Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HONDA OF AMERICA MFG., INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of HONDA OF AMERICA MFG., INC. in 12500 MERANDA RD., ANNA, OH 45302 (NAICS 336111). OSHA activity number 342912094.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Honda of America MFG., INC. — free Get an email when a new federal OSHA severe-injury report for Honda of America MFG., INC. is published. One employer, no account, unsubscribe in one click.
Site address
12500 MERANDA RD.
City
ANNA
State
OH
ZIP
45302
Mailing
12500 MERANDA RD., ANNA, OH 45302
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336111
Employees
3400
Ownership type
A

3 citations on file for this inspection.

1910.147 D04 II

Serious Gravity 5 1 instance 10 exposed
Issued
Feb 9, 2018
Abate by
Mar 7, 2018
Penalty
Initial $9,239 · Current $9,239
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):    a) Honda of America Mfg., Inc. on or about January 24, 2018, at the address of 12500 Meranda Rd. Anna, OH: The employer did not ensure that energy isolating procedures were implemented prior to performing service and maintenance activities inside the Line #1 Robotic Cell. A maintenance employee performing these tasks in a condition where a lockout device was not placed on the cells main electrical disconnect was exposed to the operating radius of the robotic arm. The employers established energy control procedure [required under 29 CFR 1910.147(d)] was not adequately utilized before the employee began the aforementioned work task inside the robotic cell.
Recent events (2)
  • — I (S) $9239
  • — Z (S) $9239

1910.147 F01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 9, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(f)(1): When lockout or tagout devices temporarily were removed from the energy isolating device and the machine or equipment was energized to test or position the machine, equipment or component thereof, the sequence of actions in 29 CFR 1910.147(f)(1)(i-v) were not followed:   a)  Honda of America Mfg., Inc. on or about January 24, 2018, at the address of 12500 Meranda Rd. Anna, OH: The employer did not ensure that employees were protected from energized components of the FMD Spin Line #1  Robotic Cell during testing activities. An employee performing calibration of the pneumatic metering cylinders contained in cell #1, was exposed to amputation hazards in that the employees hand was able to be in proximity of a pinch point near the point of operation. During this testing task, the employer did not ensure the employee was removed from the hazard or alternatively protected by means of effective machine guarding.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 5 1 instance 10 exposed
Issued
Feb 9, 2018
Abate by
Mar 7, 2018
Penalty
Initial $9,239 · Current $0 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:    a) Honda of America Mfg., Inc. on or about January 24, 2018, at the address of 12500 Meranda Rd. Anna, OH: The employer did not ensure that maintenance (authorized) employees tasked with service and maintenance activities at or near energized parts inside the FMD Spin Line #1  Robotic Cell adequately understood the application of lockout procedures in which isolate and control hazardous energy sources during both maintenance and testing tasks. Employees not understanding energy isolation application and testing procedures were exposed to energized components of the cell.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9239

View Honda of America MFG., INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342912094.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.