NORRISTOWN, PA —
OSHA Inspection: CRAZY AARON ENTERPRISES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CRAZY AARON ENTERPRISES, INC. in 710 EAST MAIN STREET, NORRISTOWN, PA 19401 (NAICS 326299). OSHA activity number 342917846.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CRAZY AARON ENTERPRISES, INC.
- Site address
- 710 EAST MAIN STREET
- City
- NORRISTOWN
- State
- PA
- ZIP
- 19401
- Mailing
- 201 SABINE AVENUE SUITE 100, NARBERTH, PA 19072
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326299
- Employees
- 4
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.101 B
- Issued
- Apr 3, 2018
- Abate by
- Apr 16, 2018
- Penalty
- Initial $5,654 · Current $3,392 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tank cars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: a) Warehouse Area - On or about January 31, 2018 compressed gas cylinders containing nitrogen and argon were not secured to prevent them from falling. b) Warehouse Area - On or about January 31, 2018 compressed gas cylinders containing nitrogen and argon were not protected from being struck by forklifts moving pallets within the warehouse area. ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement method to correct this hazard is: Comply with the Compressed Gas Association Pamphlet P-1-1965, National Fire Protection Association NFPA-55, and local government ordinances to ensure compressed gas cylinders are properly stored and protected.
Recent events (2)
- — I (S) $3392.4
- — Z (S) $5654
1910.106 H07 I A
- Issued
- Apr 3, 2018
- Abate by
- Apr 16, 2018
- Penalty
- Initial $7,068 · Current $4,241 Reduced
General-duty citation text
29 CFR 1910.106(h)(7)(i)(a): Precautions were not taken to prevent the ignition of flammable vapors. a) Production Area - On or about January 31, 2018, employees using compressed flammable aerosol without taking precautions to prevent the ignition of flammable vapors. ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement method to correct this hazard is: Comply with the equipment manufacturer's requirements and guidelines for controlling static electricity utilizing methods contained in NFPA 77 - Recommended Practice on Static Electricity, and NFPA 30 Flammable and Combustible Liquids Code. Additional methods and equipment may include static bonding and grounding methods and the wearing of anti-static clothing, overalls, boots, gloves, or static dissipative flooring and footwear.
Recent events (2)
- — I (S) $4240.8
- — Z (S) $7068
1910.106 H07 I B
- Issued
- Apr 3, 2018
- Abate by
- Apr 16, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(h)(7)(i)(b): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were being dispensed into containers without the nozzle and container being electrically interconnected. a) Production Area - On or about January 31, 2018, employees were transferring flammable liquid from a 55 gallon metal storage container into a plastic portable container without the two containers being electrically interconnected. b) Production Area - On or about January 31, 2018, employees were transferring flammable liquid from a plastic portable container into the mixing machine without the two containers being electrically interconnected. ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement method to correct this hazard is: Comply with the equipment manufacturer's requirements and follow guidelines for controlling static electricity utilizing methods contained in NFPA 77 - Recommended Practice on Static Electricity, and NFPA 30 Flammable and Combustible Liquids Code.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 A
- Issued
- Apr 3, 2018
- Abate by
- Apr 16, 2018
- Penalty
- Initial $7,068 · Current $4,241 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: a) Production Area - On or about January 31, 2018, protective equipment to prevent the buildup of static electricity was not provided for employees handling flammable liquids, vapors, and aerosols. ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement method to correct this hazard is: Comply with the equipment manufacturer's requirements and guidelines for controlling static electricity utilizing methods contained in NFPA 77 - Recommended Practice on Static Electricity, and NFPA 30 Flammable and Combustible Liquids Code. Additional methods and equipment may include the wearing of anti-static clothing, overalls, boots, and gloves.
Recent events (2)
- — I (S) $4240.8
- — Z (S) $7068
1910.134 C01
- Issued
- Apr 3, 2018
- Abate by
- Apr 16, 2018
- Penalty
- Initial $4,240 · Current $2,544 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) Production Area - On or about January 31, 2018, the employer did not establish a written respiratory protection program for employees required to use a 3M Brand Model 8233 Particulate Respirator.
Recent events (2)
- — I (S) $2544
- — Z (S) $4240
1910.134 E01
- Issued
- Apr 3, 2018
- Abate by
- Apr 16, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Production Area - On or about January 31, 2018, the employer did not provide a medical evaluation for employees required to use a 3M Brand Model 8233 Particulate Respirator.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F01
- Issued
- Apr 3, 2018
- Abate by
- Apr 16, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting face piece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a) Production Area - On or about January 31, 2018, employees required to use a 3M Brand, Model 8233 Particulate Respirator were not provided with the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) .
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C04 I
- Issued
- Apr 3, 2018
- Abate by
- Apr 16, 2018
- Penalty
- Initial $7,068 · Current $4,241 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Production Area - On or about January 31, 2018 energy control procedures were not developed for the control of multiple sources of hazardous energy associated with the mixing machine.
Recent events (2)
- — I (S) $4240.8
- — Z (S) $7068
1910.157 C01
- Issued
- Apr 3, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) Production Area - On or about January 31, 2018 portable dry chemical fire extinguishers were located on the floor and were not mounted.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Crazy Aaron Enterprises, INC.
View Crazy Aaron Enterprises, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326299)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342917846.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.