GREENCASTLE, PA —
OSHA Inspection: APX MITCHELL MACHINE SHOP
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of APX MITCHELL MACHINE SHOP in 550 SOUTH MOLLY PITCHER HIGHWAY, GREENCASTLE, PA 17225 (NAICS 332710). OSHA activity number 342920014.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- APX MITCHELL MACHINE SHOP
- Site address
- 550 SOUTH MOLLY PITCHER HIGHWAY
- City
- GREENCASTLE
- State
- PA
- ZIP
- 17225
- Mailing
- 550 SOUTH MOLLY PITCHER HIGHWAY, GREENCASTLE, PA 17225
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 12
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.219 H01
- Issued
- Feb 22, 2018
- Penalty
- Initial $2,956 · Current $2,069 Reduced
General-duty citation text
29 CFR 1910.219(h)(1): Projecting key(s), setscrew(s), or other projections in revolving part(s) were not removed, made flush, or guarded by metal cover(s): a) Deburring Machine - The employee using the deburring machine was exposed to a rotating part hazard from the setscrews protruding from the rotating shaft, on or about February 1st, 2018. No abatement certification or documentation required.
Recent events (2)
- — I (S) $2069.2
- — Z (S) $2956
1910.242 B
- Issued
- Feb 22, 2018
- Penalty
- Initial $1,885 · Current $1,320 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Conquest V1000 - An employee using compressed air to blow off parts in the CNC machine was exposed to struck-by hazards from using compressed air measuring over 100 psi, on or about February 1st, 2018. b) GX1000 - An employee using compressed air to blow off parts in the CNC machine was exposed to struck-by hazards from using compressed air measuring over 60 psi, on or about February 1st, 2018. No abatement certification or documentation required.
Recent events (2)
- — I (S) $1319.5
- — Z (S) $1885
1910.157 E02
- Issued
- Feb 22, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: a) Fire Extinguishers - Fire extinguishers were not inspected on a monthly basis exposing employees to possible fire hazards, on or about February 1st, 2018. Note: Applies to any extinguishers provided in the workplace. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B02
- Issued
- Feb 22, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Mill Readout - An employee using the mill was exposed to an electrical hazard from a unapproved receptacle outlet attached to the end of a flexible cord, on or about February 1st, 2018. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Feb 22, 2018
- Abate by
- Mar 13, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of the standard: a) Sander - An employee using the belt sander was exposed to possible electrical hazards from an extension cord used as permanent wiring, on or about February 1st, 2018. b) Deburring Machine - An employee using the deburring machine was exposed to possible electrical hazards from an extension cord used as permanent wiring, on or about February 1st, 2018. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 332710)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342920014.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.