Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VIVINT SOLAR, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VIVINT SOLAR, INC in 260 MAIN ST, EAST LONGMEADOW, MA 01028 (NAICS 238160). OSHA activity number 342923711.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vivint Solar, INC — free Get an email when a new federal OSHA severe-injury report for Vivint Solar, INC is published. One employer, no account, unsubscribe in one click.
Establishment
VIVINT SOLAR, INC
Site address
260 MAIN ST
City
EAST LONGMEADOW
State
MA
ZIP
01028
Mailing
1800 WEST ASHTON BOULEVARD, LEHI, UT 84043
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
251
Ownership type
A

1 citation on file for this inspection.

1926.502 D16 III

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 5, 2018
Penalty
Initial $50,815 · Current $12,934 Reduced
29 CFR 1926.502(d)(16)(iii): Fall protection systems were not rigged such that an employee can neither free fall more than 6 feet (1.8 m), nor contact any lower level:    a) 260 Main St., East Longmeadow, MA: On or about February 1, 2018, 2 employees were observed working on the roof of this residence, with their fall protection system set up in such a fashion that they would have struck the lower level (ground) if they fell the more than 12 feet to the ground below.      Vivint Solar, Inc.) was previously cited for a violation of this occupational safety 29 CFR 1926.502 (d) 16, which was contained in OSHA inspection number1091796, citation number 1, item number 1and was affirmed as a final order on 10/22/2015 with respect to a workplace located at 1 Pine St., Delmar, NY.    Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29CFR1903.19(d)(1).
Recent events (2)
  • — I (S) $12934
  • — Z (R) $50815

View Vivint Solar, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342923711.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.