COLORADO SPRINGS, CO —
OSHA Inspection: ROOB CONSTRUCTION, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ROOB CONSTRUCTION, LLC in 5190 VESSEY ROAD, COLORADO SPRINGS, CO 80908 (NAICS 238130). OSHA activity number 342925377.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROOB CONSTRUCTION, LLC
- Site address
- 5190 VESSEY ROAD
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80908
- Mailing
- 1429 JET WING CIRCLE, COLORADO SPRINGS, CO 80916
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Feb 12, 2018
- Abate by
- Feb 16, 2018
- Penalty
- Initial $2,772 · Current $2,772
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On or about January 29, 2018, and at times prior to that date, employees were exposed to injuries from falls in excess of six feet, while walking top plates to set roof trusses, without the benefit of fall protection systems being in place.
Recent events (1)
- — Z (S) $2772
1926.501 A02
- Issued
- Feb 12, 2018
- Abate by
- Feb 16, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(a)(2): The employer did not determine if the walking/working surfaces on which its employees were to work on, had the strength and structure integrity to support employees safely: (a) On or about January 29, 2018, employees were exposed to fall and struck-by hazards, while working beside and in-between wooden roof trusses that were not adequately secured and/or braced to prevent them from displacing.